EasyManuals Logo

GGP Mountfield SV-150 User Manual

GGP Mountfield SV-150
35 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
B) Checking the ignition off microswitch
11 Remove the upper conveyor [ 6.1.A
].
12 Disconnect the faston (11) from the coil.
13 Using an Ohmmeter tester, make contact with
the prods on terminals “1-COM” and “3-NO” of
the microswitch (12); the instrument should
read:
- = microswitch pressed
- 0 = microswitch free
14 Remount the upper conveyor [ 6.1.A
].
C) Checking the brake
21 Remove the conveyor with the tank [ 6.1.A
].
22 Check that the clutch lining (13) is at least 2 mm
thick at the thinnest point.
23 Make sure that the control lever (14) moves
freely and remove any remains of grass and
mud.
24 Reconnect the petrol pipe and start the engine.
Release the lawnmower lever and check that
the engine stops within 3 seconds.
25 If it stops after 3 seconds, replace the entire
assembly [ point “D”
], because the spring or
clutch lining is unable to guarantee the right
braking times.
26 Remount the conveyor [ 6.1.A
].
WARNING! Never return the lawnmower to
your client without checking brake efficiency.
SV 150
6.7.0
TURNING OFF AND STOPPING THE ENGINE
2 / 3

WORKSHOP MANUAL
page
from
2004 to ••••
01/2005
13
14
> 2 mm
12
11
PRINT