- 15 - Hardware Installation
Socket
Socket
Security
Security Serve r
Operating Properties
Power S upply
Power Supply 2 x 2200W redundant PSUs
80 PLUS Platinum
AC Input:
100-127V~/ 14A, 47-63Hz
200-240V~/ 12.6A, 47-63Hz
DC Output:
Max 1200W/ 100-127V~
+12.12V/ 95.6A
+12Vsb/ 3.5A
- Max 2200W/ 200-240V
+12.12V/ 178.1A
+12Vsb/ 3.5A
NOTE:
The system power supply requires C19 type power cord
2000W 80 PLUS Titanium PSU as an option
Socket
Socket
Security
Security Serve r
Operating Properties
Power S upply
System
Management
Aspeed® AST2500 management controller
Avocent® MergePoint IPMI 2.0 web interface:
Network settings
Network security settings
Hardware information
Users control
Services settings
IPMI settings
Sessions control
LDAP settings
Power control
Fan proles
Voltages, fans and temperatures monitoring
System event log
Events management (platform events, trap settings, email settings)
vKVM & vMedia (HTML5)
Socket
Socket
Security
Security Serve r
Operating Properties
Power S upply
Operating
Properties
Operating temperature: 10°C to 35°C
Operating humidity: 8-80% (non-condensing)
Non-operating temperature: -40°C to 60°C
Non-operating humidity: 20%-95% (non-condensing)
Socket
Socket
Security
Security Serve r
Operating Properties
Power S upply
System
Dimension
2U 4 Nodes - Rear access
440 x 87 x 820