Page #2 background image
System 3000
Blind timer and timer Display
Ƙ Switch between manual operation and automatic operation
ƞ / Ɵ Operation of the insert and navigation in the menu
ƣ Call up and terminate the programming menu
3 Function
Intended use
Manual and time-controlled operation of Venetian blinds, shutters, awnings or lighting
Operation switching, dimming or Venetian blind insert or 3-wire extension of System 3000
Product characteristics
Current time can be saved as switching time, quick programming
Automatic summer/winter time changeover, can be switched off
Switching at sunrise and/or before sunset (Astro function) adjustable for 18 countries
Astro time shift for sunrise and sunset
Disabling function
Display switches off after 2 minutes,
Permanent indication of the current time possible
Depending on the insert used
Activation of blind/shutters
Programming of one up time and one down time each for the parts of the week Mo-Fr and
Sa+Su
Ventilation position of the blind/shutter can be saved
Switching and dimming of lighting
Programming of two memory areas with one switch-on and one switch-off time each for
the parts of the week Mo-Fr and Sa+Su
Switch-on brightness of lighting can be saved, with dimming insert
Behaviour after a mains voltage failure
Voltage failure less than 4 hours
All data and settings are preserved
Missed switching times are not performed later
Voltage failure greater than 4 hours
Year flashes and no switching operations are executed
Date and time must be set again
All switching times are preserved
Default setting
Switching times on a Venetian blind insert:
ƞ 07:00, Mo - Fr
Ɵ 21:00, Mo - Fr
ƞ 09:00, Sa - Su
Ɵ 21:00, Sa - Su
Switching times on a switching or dimming insert, memory area ƙ:
on
16:00, Mo - Fr
off
09:00, Mo - Fr
on
16:00, Sa - Su
off
09:00, Sa - Su
No switching times are stored in the second memory area Ʀ
Astro function is active with times for Germany (+49)
Automatic mode is active
Automatic summer/winter time changeover is active
2 / 10
32596512 10865949 10.07.2018

Other manuals for Gira System 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gira System 3000 and is the answer not in the manual?

Gira System 3000 Specifications

General IconGeneral
Operating voltage230 V AC
Protection typeIP20
Type of connectionScrew terminals
Housing MaterialPlastic
TypeControl Unit
CompatibilityGira System 3000
Ambient temperature+45 °C
Power SupplyMains power