EasyManua.ls Logo

GIWEE CCG-D24HR4-GSC-S40 - User Manual

Default Icon
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Service Manual
-- R32 Multi Split Unit
2021.05

Table of Contents

Questions and Answers

  • H
    harringtonfrankAug 8, 2025
    Why is my GIWEE Air Conditioner blowing mist?
    • H
      hayesashleyAug 8, 2025
      When the room humidity is relatively high, the cooling or defrosting process in heating mode ends, the air outlet may release water mist. This is a normal physical phenomenon.
  • R
    Rebecca NelsonAug 13, 2025
    What to do if GIWEE Air Conditioner won't stop blowing air after shut down?
    • B
      bcrawfordAug 13, 2025
      If your GIWEE Air Conditioner doesn't blow air immediately after shutting down in cooling mode, the drying function may be enabled. Wait for it to finish, or use the remote to disable it. Also, the louver will close after 30 seconds.
  • R
    Richard LeeAug 18, 2025
    Why is no air blowing out at the start of heating operation in GIWEE Air Conditioner?
    • C
      Casey PerezAug 18, 2025
      If your GIWEE Air Conditioner doesn't blow air when starting heating, it's preventing cold air from blowing until the indoor heat exchanger warms up. This usually takes 2 to 5 minutes.
  • J
    Julie PetersonAug 23, 2025
    Why is my GIWEE CCG-D24HR4-GSC-S40 Air Conditioner not blowing air for 6-12 minutes in heating mode?
    • E
      Elizabeth HeathAug 23, 2025
      If your GIWEE Air Conditioner doesn't blow air for 6 to 12 minutes in heating mode, it might be defrosting automatically due to low outdoor temperature and high humidity. Please wait. Water or steam may come from the outdoor unit during defrosting.
  • A
    adamnguyenAug 28, 2025
    Why is air not blowing out during dehumidification operation in my GIWEE Air Conditioner?
    • J
      Jesus HarrisonAug 28, 2025
      If your GIWEE Air Conditioner doesn't blow air during dehumidification, the indoor fan might stop to prevent moisture evaporation and save energy.
  • A
    Amber HodgesSep 2, 2025
    How to restart GIWEE CCG-D24HR4-GSC-S40 immediately after shut down?
    • L
      Lisa HickmanSep 2, 2025
      To protect the unit, there is a 3-minute delay before a GIWEE Air Conditioner can restart after being shut down, indicated by the RUN lamp being ON. This protection timer activates automatically when power is connected.

Summary

I. Specifications

2. Specification

Details technical specifications for outdoor units.

5. Wiring diagram

Illustrates electrical connections for outdoor units.

II. Installation

2. Selecting installation place

Guidelines for choosing optimal indoor and outdoor unit locations.

4. Installation of wall mounted unit

Step-by-step instructions for installing wall-mounted units.

5. Installation of cassette unit

Procedures for installing cassette type indoor units.

6. Installation of ducted unit

Instructions for installing ducted type indoor units.

7. Installation of console

Steps for installing console type indoor units.

8. Refrigerant pipe connection

Detailed procedures for connecting refrigerant pipes.

9. Wiring connection

Guidelines for making electrical connections between units.

10. Air purging

Steps for removing air and moisture from the refrigerant system.

14. Test operation

Steps for performing the final test operation after installation.

III. Troubleshooting

1. Error code list

Lists digital display codes and corresponding error descriptions.

GIWEE CCG-D24HR4-GSC-S40 Specifications

General IconGeneral
BrandGIWEE
ModelCCG-D24HR4-GSC-S40
CategoryAir Conditioner
LanguageEnglish

Related product manuals