Glentek Inc. 208 Standard Street, El Segundo, California 90245, U.S.A. (310) 322
SMA7130, SMA71075 and SMA71100 MANUAL
RECOMMENDATIONS FOR GLENTEK AMPLIFIERS
All amplifiers installed in a NEMA 12 enclosures or equivalent with wiring in metal conduit or
enclosed metal wire trough (see Shielding and segregation).
Use Glentek shielded feedback and motor cables.
An AC line filter properly installed in a NEMA 12 enclosure or equivalent (see Filtering).
AC line filters for single-phase applications
1A-15A input current, 120-250VAC use: Corcom 15ET1 or equivalent.
15A-25A input current, 120-250VAC use: Corcom 25FC10 or equivalent.
25A-36A input current, 120-250VAC use: Corcom 36FC10 or equivalent.
AC line filters for 3-phase applications
1A-25A input current, 120-250VAC use: Corcom 25FCD10 or equivalent.
25A-36A input current, 120-250VAC use: Corcom 36FCD10 or equivalent.
36A-50A input current, 120-250VAC use: Corcom 50FCD10 or equivalent.
50A-80A input current, 120-250VAC use: Corcom 80FCD10 or equivalent.
APPENDIX C: EUROPEAN UNION EMC DIRECTIVE