9
Reset
If the motor needs to be initialised after the first setup, bridge a wire
between terminals 1 and 7 for 5 seconds. The inverter will relearn the
travel limits.
Maintenance
Maintenance should be performed every 6 months with attention paid
to the open and closed physical stops, gear rack and the operation of
safety devices.
LOGICS
Logic
“Security”
Ped
Close
Stop
Safety device
Closed
Partial opening
close after pause
No effect
Open Disabled
No effect
Opening
No effect
Closes
Stops operation
If toggled off then
on stops then
close
immediately
Open in pause
Reset timer
Closes
Stops operation
If toggled off then
on - closes
Closing
Opens
No effect
Stops operation
Opens
Stopped
No effect
Closes in slow
No effect
No effect
Logic “Timer”
Ped
Close
Stop
Safety device
Closed
Partial opening
close after pause
No effect
Open Disabled
No effect
Opening
No effect
Closes
Stops operation
No effect
Open in pause
Reset timer
Closes
Stops operation
Reset timer
Closing
Opens
No effect
Stops operation
Opens
Stopped
No effect
Closes in slow
No effect
No effect