COMPACT DUAL FLOW
5-CHEMICAL DISPENSER
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or service the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage. Retain instructions for future reference.
SPECIFICATIONS
Dimensions
(approx) (in)
H 14” x W 6” x D 3-3/4”
Weight (approx) 3 .5 lbs
Installation Working temperature range 40 – 150
O
F
Working pressure range 30 – 70 PSI
Minimum water ow required:
High ow = 8.5L/min
Low ow = 3.5L/min
Dilution 13 independent dilution ratios
High Flow 6:1 - 570:1
Low Flow 2:1 - 230:1
Material Cover/Backplate/Dial Selector:
Glass Bead Polypropylene (GBPP)
Proportioner Pusher: ABS
Internal tubing and seals: EPDM
Model 670171
ORDER YOUR CONCENTRATED CLEANING CHEMICALS
Visit www.globalindustrial.com or call 1-800-645-1232
Floor Cleaner Heavy-Duty Cleaner/Degreaser Glass & Mirror Cleaner Multipurpose Degreaser
Model #670172 Model #670173 Model #670174 Model #670175
(1 Gallon Bottle/Case of 2) (1 Gallon Bottle/Case of 2) (1 Gallon Bottle/Case of 2) (1 Gallon Bottle/Case of 2)

Questions and Answers

  • K
    Kaitlyn KnappJul 28, 2025
    Why is there no water flow from my Global Dispenser?
    • T
      Timothy SandersJul 28, 2025
      If you're experiencing no water flow from your Global Dispenser, several factors could be responsible. First, check the water connection to ensure it is properly connected. A malfunctioning water valve can also cause this issue, in which case the valve should be replaced. Additionally, the outlet may be blocked, requiring you to unblock or replace the affected part. Finally, excessive water pressure (over 70PSI or 5 bar) can be the cause; fitting a water regulator to the mains supply should resolve this.
  • P
    Patricia WardAug 5, 2025
    What to do if there is no chemical suction in my Global 670171?
    • K
      Kelsey WilliamsAug 5, 2025
      If your Global Dispenser isn't suctioning chemicals, several factors could be at play. Here's what to check: 1. Ensure you have a minimum of 30PSI running water (2 bar). 2. Inspect the tube for any kinks and re-route if necessary. 3. Verify that the chemical container is not empty and replenish if needed. 4. Check for a blocked foot valve, and clean or replace it. 5. Examine the dilution valve for blockages and clean the part. 6. Confirm the dilution clamp is secure to prevent a loose dilution valve. 7. See if the flood ring in the outlet has moved and replace the outlet tube assembly if needed.
  • J
    John WhiteAug 12, 2025
    How to fix a Global Dispenser that will not shut-off?
    • A
      Alexander BakerAug 12, 2025
      If your Global Dispenser won't shut off, it could be due to a couple of reasons. First, check if the unit has a lock-on feature activated; if so, push the operating button to deactivate it. Alternatively, a malfunctioning water valve might be the cause, requiring a replacement of the water valve.
  • R
    Ronald McbrideAug 20, 2025
    Why is my Global Dispenser dispensing too much chemical?
    • E
      Erica FullerAug 20, 2025
      If your Global Dispenser is dispensing too much chemical, it could be due to the dilution pin being on the wrong setting; try changing the ratio. Another potential cause is the chemical stiffening; in this case, lower the chemical below the unit injection point.

Summary

Safety and Handling Instructions

Instructional Adherence

Emphasizes reading and saving instructions for safe operation and injury prevention.

Installation Guide

Mounting the Dispenser

Step-by-step instructions on how to fix the dispenser to the wall.

Chemical Dilution Setup

Setting Dilution Ratios

Instructions on how to adjust dilution clips and pins for desired ratios.

Limited Warranty Information

Warranty Terms and Exclusions

Details the two-year limited warranty, exclusions, and limitations of liability.

Compliance, Safety, and Maintenance

Maintenance Recommendations

Advises on calibrating dilution ratios and periodic flushing for optimal performance.

Troubleshooting Common Issues

No Water Flow or Unit Shut-off Problems

Diagnoses and solutions for issues like no water flow or unit failing to shut off.

Chemical Suction and Dilution Issues

Addresses problems with chemical suction, excess chemical, or incorrect dilution.

Dilution Reference Chart

Dilution Ratio Settings

Provides a chart for setting dilution ratios based on pin position and flow rate.

Global 670171 Specifications

General IconGeneral
BrandGlobal
Model670171
CategoryDispenser
LanguageEnglish