EasyManua.ls Logo

Glow-worm 18si - Replacement of Parts

Glow-worm 18si
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
42
4000123942-2
18 Replacement of Parts
IMPORTANT INFORMATION
WARNING: Before commencing the replacement of any
component, isolate appliance from electrical supply and turn
off gas at service cock.
Replacement of parts must be carried out by a competent
person.
When replacing components it may be necessary to renew
sealing washers, gaskets and 'O' rings. If new ones are
supplied with replacement components they must be used.
All parts are replaced in reverse order to removal.
If any gas-carrying components are disturbed, removed or
replaced it will be necessary on completion of assembly to test
for gas soundness and purge in accordance with the current
issue of BS6891 or in IE, the current edition of I.S.813 "Domestic
Gas Installations".
18.1 Central heating thermistor
Before starting refer to the front of Section 18 Important
information.
• Remove the front panel, refer to Section 15.3.
• Lower the control panel, refer to Section 15.4.
• Locate central heating thermistor on heating flow pipe on
centre of boiler, see diagram 18.2.
• Unclip thermistor from pipe.
• Disconnect electrical connections from thermistor.
• Fit electrical connections to replacement thermistor and fit
thermistor to pipe. The polarity is not important.
Diagram 18.2
9821
CENTRAL HEATING
THERMISTOR
Diagram 18.1
To Drain the central heating circuit
• Open drain valve fitted at the lowest point in the system.
• Allow air into the system by opening a radiator bleed screw or the boilers drain
valve (f).
To Drain the Domestic hot water circuit (24ci Only)
• Close boiler isolating valve (d).
• Turn on one or more hot water taps.
To Drain the boiler
• Close the isolating valves (a), (d) and (e) .
• Open the boiler drain valve (f).
24ci shown
(f)
BOILER DRAIN VALVE
9839
Note: Isolating cocks water and gas are shown in the: OFF position
(e)
(d)
(a)
HEATING
RETURN
COLD WATER
INLET (24ci Only)
HEATING
FLOW
24ci shown
DOMESTIC HOT
WATER OUTLET
(24ci Only)
GAS SERVICE
COCK
11933
(b)
(c)