22
4000123923-2
10316
Diagram 10.8
RESTRICTOR
(30ci/30si only)
FAN
10 Horizontal Telescopic Rear Flue Installation
10.3 Fan Removal, refer to diagram 10.5
• Disconnect power supply leads and earth lead from fan.
• Unscrew and remove the two fan retaining bolts.
• Ease the fan down and forwards to remove.
10.4 Flue Connection, refer to diagram 10.6
Pull the flue assembly into the spigot bayonet connection and
twist anti-clockwise to lock.
10.5 Flue Hood Outlet Restrictor, refer to
diagram 10.7 (for 35 ci only)
Secure restrictor, supplied with flue pack, to the flue hood as
shown in diagram 10.7.
10.6 Restrictor, refer to diagram 10.8
For flue systems less than 0.5m long, fit the flue restrictor
supplied in document envelope into the fan outlet (30ci/30si
only), see diagram 10.8.
10.7 Fan Securing, refer to diagram 10.5
Ensure fan outlet seal is in position, see diagram 10.5, then fit
the fan into the flue duct and secure to the flue collector with
screws previously removed.
Replace chamber cover and secure with screws previously
removed.
Diagram 10.6
Diagram 10.5
9741
POWER
SUPPLY
LEADS
EARTH
LEAD
FAN RETAINING
BOLTS
TWIST ANTI-CLOCKWISE
& LOCK AT 90
O
POSITION
NOTE: Please check orientation
when engaging bayonet spigot
SEAL
10316
Diagram 10.7
RESTRICTOR
(35ci only)
FLUE
HOOD