EasyManua.ls Logo

Glow-worm 30si - Domestic Hot Water Design (30 ci); Hot Water System Requirements

Glow-worm 30si
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
4000123923-2
General - All domestic hot water circuits, connections, fittings
must be in accordance with the relevant standards and water
supply regulations.
For GB: Guidance G17 to G24 and recommendation R17 to
R24 of the Water Regulation Guide.
For IE: The current edition of I.S.813 "Domestic Gas Installations".
• Copper tubing or plastic Hep
2
0 may be used for the domestic
hot water system. Unnecessary pressure losses should be
avoided.
• Provision shall be made for a drain valve at the lowest points
of the system.
• The flow restrictor, supplied in the document envelope, must
be fitted as diagram 7.1, limiting the flow through the boiler to
a maximum of 12 litres/min for 30 ci and 14 litres/min for 35 ci.
• The boiler will operate with a minimum supply pressure of 0.5
bar, at a reduced flow rate.
Best operating performance will be obtained from a supply
pressure of 1 bar or greater.
4.1 Hard Water Areas
In areas where the water is 'hard', more than 200mg/litre, it is
recommended that a proprietary scale reducer is fitted in the
cold water supply to the boiler.
4 Domestic Hot Water System Design. 30ci Only

Other manuals for Glow-worm 30si

Related product manuals