34 Installation and maintenance instructions Betacom 4 0020238424_04
– Clearance for the ignition electrodes: 3.5 to 4.5 mm
6. Make sure that the seal (5) is free from damage.
▽ If necessary, replace the seal.
12.10 Cleaning the condensate tray
1. Switch off the product via the main switch.
2. Close the gas isolator cock.
3. Remove the front casing. (→ Page 16)
4. Remove the screw (1).
5. Push the clip upwards.
6. Remove the flue gas pipe (2).
7. Using water to clean the condensate tray (1).
◁ The water runs out into the condensate siphon.
12.11 Cleaning the condensate siphon
1. Unclip the lower section of the siphon (1) from the up-
per section of the siphon (2).
2. Remove the float (3).
3. Flush out the float and lower section of the siphon with
water.
4. Fill the lower section of the siphon with water up to 10
mm below the upper edge of the condensate discharge
pipe.
5. Re-insert the float (3).
Note
Check whether the float is present in the
condensate siphon.
6. Clip the lower section of the siphon (1) into the upper
section of the siphon (2).
12.12 Cleaning the strainer in the cold water inlet
1. Close the main cold water supply line.
2. Drain the product on the domestic hot water side.
3. Remove the connector from the connection for the pro-
duct's cold water pipe.
4. Clean the strainer in the cold water inlet without remov-
ing it.