8 Operating instructions Compact 0020313974_00
for longer than two minutes. The display
either shows the target flow temperature
(if no control is connected) or the message
on and/or oF (if a control is connected).
The basic display (B) shows the current
product status. If you press a selection
button, the activated function is displayed
in the display.
The functions that are available depend
on whether a control is connected to the
product.
To return to the basic display, press .
5.1.2 Operating levels
The product has two operating levels:
The end user level shows the informa-
tion and offers setting options which do
not require any special prior knowledge.
Specialised knowledge is required in or-
der to use the installer level (access for
competent persons). This is therefore
protected by an access code.
5.2 Setting the heating flow
temperature
Condition: No control connected
In the basic display, press once to
ensure that the symbol flashes.
The set heating flow temperature
appears in the display.
Press or to set the required
heating flow temperature.
Confirm by pressing .
The set temperature flashes twice
rapidly.
Condition: Control connected
In the basic display, press once to
ensure that the symbol flashes.
on or oF appears in the display.
on indicates that heating mode is
switched on.
oF indicates that heating mode is
switched off.
If oF is shown in the display, press the
button to switch on heating mode.
Confirm by pressing .
on flashes twice rapidly.
Set the required heating flow temperat-
ure on the control ( Control operating
instructions).
5.3 Setting the domestic hot water
temperature
1. Press twice in the basic display to
ensure that the symbol flashes.
The set domestic hot water temper-
ature appears in the display.
Condition: No control connected
Press or to set the required
water temperature.
Confirm by pressing .
The set temperature flashes twice
rapidly.
Condition: Control connected
Set the required domestic hot water
temperature on the control ( Control
operating instructions).
5.4 Switching off heating mode
(Summer mode)
Condition: No control connected
To switch off heating mode, press .
The value of the heating flow temper-
ature appears in the display.
Press to reduce the heating flow
temperature and set it to oF.
Confirm by pressing .
oF flashes twice rapidly, heating
mode is deactivated.
The symbol is no longer shown in
the display.

Other manuals for Glow-worm Compact 28c-AS/1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Glow-worm Compact 28c-AS/1 and is the answer not in the manual?

Glow-worm Compact 28c-AS/1 Specifications

General IconGeneral
BrandGlow-worm
ModelCompact 28c-AS/1
CategoryBoiler
LanguageEnglish

Related product manuals