EasyManua.ls Logo

Glow-worm Envirosorb 5 - Access to Main Board; Electrical Wiring; Main Board

Glow-worm Envirosorb 5
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
0020111744_00 - 09/10 - Glow-worm
- 15 -
INSTALLATION
Electrical components have been tested to meet the equivalent
requirements of BSEN 7671 and the BEAB regulations.
The cables connecting the switchboard and the heat pump must
be:
- Suitable for a xed installation.
- weather resistant.
- equipped with wires adapted to appliance’s power rating.
Connect the heat pump to an electrical panel via an
independent protection system (20A differential breaker with
at least 3 mm between each contact).
Additional protection may be required during installation to
ensure surge category II.
11.1 Main board
20 mm max.
1
2
Key
1 Electrical wires
2 Insulation
When you connect the electrical wires to a connector on the
electronic board:
Keep a distance of a maximum of 20 mm between connector
and the start of the insulation (2).
11.2 Access to main board
B
A
2
1
Key
1 Handle
2 Box
Remove the box (2) by pulling it toward you using the handle
(1).
11.3 Electrical wiring
e
Insert the Ebus 24V cable and 230V power cable
in different casings.
B
A
5
4
3
2
1
6
Key
1 230 V supply connection terminal block
2 BUS connection terminal
3 Gland for Ebus cable
4 Gland for 230 V power cable
5 Access hatch to electrical connections
6 Access hatch screw
Remove the screw (6) from the access hatch (5).
Open the access hatch (5).
Ebus Connection
Connect a 2 x 0.75 mm ² cable to the appliance’s BUS
terminal (2).
Pass the cable through the gland (3).
Connect the Ebus cable to the system control unit.
Tighten the gland.
230V Connection
Connect a 3 x 2.5 mm ² cable to the appliance’s power
terminal 230 (1).
Pass the cable through the gland (4).
Connect the appliance’s power cable to the installation’s
electrical panel: single-phase network 230V + neutral +
earth.
Close the access hatch with the screw (6).
Tighten the gland.