0020096321_01 - 02/11 - Glow-worm
- 9 -
Key
1 2 port valve "heating zone 1"
2 Heating circuit zone 1
3 Climapro2 RF programmable wireless room thermostat "zone 1"
4 2 port valve "heating zone 2"
5 Heating circuit zone 2
6 Climapro2 RF programmable wireless room thermostat "zone 2"
7 2 port valve "heating zone 3"
8 Climapro2 RF programmable wireless room thermostat "zone 3"
9 Heating circuit zone 3
10 Systempro control unit
A Heating circuit return
B Heating circuit ow
Application conditions
- The Systempro control unit manages up to 3 heating zones.
- Each wireless room thermostat can control a heating zone.
- Zones must be same temperatures.
- The installation can be performed with a low-temperature
under oor heating (heating outlet temperature < 50°C) or low
temperature radiators (heating outlet temperature < 70°C).
e
Use 0.75 mm² section cables for the electrical
connections to the control unit.
Control unit settings
Description of main settings Setting
Did you install a multizone kit ? Yes
Max. heating ow temperature for the low
temperature zone
T < 30°C
Max. heating ow temperature for the high
temperature zone
T < 70°C
2 port valve electrical connections
- When the 2 port valve is connected to REL3:
Connect the neutral wire (blue) of the valve to the “N” of the
REL3 connector.
Connect the live wire (brown) of the valve to the “L” of the REL3
connector.
Connect the earth wire (yellow/green) of the valve to the earth
of the REL3 connector.
Electrically insulate the red and grey wires of the valve as they
are not used.
- When the 2 port valve is connected to REL4 or 5:
Connect the neutral wire (blue) of the valve to the “N” and
the live wire (brown) of the valve to the “L” of the REL4 or 5
connector.
Connect the earth wire (yellow/green) of the valve to the earth
of the REL3 connector.
Electrically insulate the red and grey wires of the valve as they
are not used.
INTRODUCTION
EN

Other manuals for Glow-worm Envirosorb 5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Glow-worm Envirosorb 5 and is the answer not in the manual?

Glow-worm Envirosorb 5 Specifications

General IconGeneral
BrandGlow-worm
ModelEnvirosorb 5
CategoryHeat Pump
LanguageEnglish

Related product manuals