6.2 Domestic hot water
i
The lower the temperature of the hot water, the more
economical the heat pump.
1 Select Hot water on the
screen.
2 Set max.Domestic Hot
Water temperature.
6.3 Cooling
Function not active for the UK.
6.4 HP Management
This menu is used to set the outside temperature from which the
heat pump must turn o (value adjustable from -20°C to 20°C,
factory setting: 0°C).
To take full advantage of the heat pump, we recommend you to set:
- "-5°C" for 5 kW heat pump because it can not operate below -5°C.
- "-20°C" for the other heat pumps.
1 Select HP Management on
the screen.
2 Select Heat pump stop
temp. on the screen.
3 Set the outside
temperature from which the
heat pump must turn o .
Case of a heat pump controlled by On/O contact
Refer to the heat pump installation notice to access the “after-
sales” parameters listed below.
Set the heat pump heating curves complying with the
correspondences with the Systempro control unit heating
curves (see table below).
b
Incorrectly setting these parameters may signi cantly
impact the system e ciency.
- Setting of the heat pump parameter 112:
Heating curve of the Systempro
control unit
Heating curve
of the heat pump
0.1 02 7
0.3 0.4 8
0.5 0.7 9
0.8 0.9 10
1.0 1.2 11
1.3 Max. 12
- Example: Setting of the heat pump parameter 112:
Heating curve of the Systempro
control unit
Heating curve
of the heat pump
0.1 0.2 7
0.3 0.4 8
0.5 0.7 9
0.8 0.9 10
1.0 1.2 11
1.3 Max. 12
In the case where the MODUZONE Z20 or Z30 option is installed:
if the curve setting is "1.2" on the control unit, the curve setting
will be "11" for heat pump parameter 112.
6.1.3 Pre heating
The control unit manages the heating by anticipating the change
in temperature setting between two programmed time ranges.
This function allows it to reach the programmed temperature
more rapidly (factory setting: active). It acts at the rst morning
setting change for each zone.
1 Select Pre heating on the
screen.
2 Con rm your choice.
INSTALLATION
EN

Other manuals for Glow-worm Envirosorb 5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Glow-worm Envirosorb 5 and is the answer not in the manual?

Glow-worm Envirosorb 5 Specifications

General IconGeneral
BrandGlow-worm
ModelEnvirosorb 5
CategoryHeat Pump
LanguageEnglish

Related product manuals