4 - Open the clip of the ONE-PUMP system on the
central strut. Before folding your wing, make sure
that the neoprene protection covers the clip so as
not to damage it.
5 - Roll one extremity of the wing inward towards the
center and closing tightly so all the air is pushed
out.
1 - Return the dried extrado wing to the ground,
leading edge towards the wind.
2 - Remove the neoprene protection and unscrew
the lower part of the ination and deation valves.
Take o the neoprene protection and unscrew the
lower part at the base of Valve. Be careful not to
lose the joint of the plug.
3 - Remove the ber battens for the WING PULSE.
WING DEFLATION
6 - Proceed the same way from the other end to the central strut. Fold the two rolled up ends one over the
other. Fold your wing in 2 or 3 parts, beginning with the trailing edge of the wing, while evacuating the air
gradually. The connector of the One-Pump System is narrow, it will take patience not to risk over-pressuring
the bladder.
7 - Store it in the bag.