EasyManua.ls Logo

Goodman AVPTC37C14 - User Manual

Goodman AVPTC37C14
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
AVPTC**14** AIR HANDLERS


© 2018-2021, 2023
Daikin Comfort Technologies Manufacturing, L.P.
19001 Kermier Rd., Waller, TX 77484
www.goodmanmfg.com - or - www.amana-hac.com
P/N: IOA-4030H Date: April 2023
is a registered trademark of Maytag Corporation or its related companies and is used under license. All rights reserved.

Prior to installation, thoroughly familiarize yourself with this Installation
Manual. Observe all safety warnings. During installation or repair,
caution is to be observed. It is your responsibility to install the product
safely and to educate the customer on its safe use.


This device, which was assembled by Daikin Comfort
Technologies Manufacturing, L.P., contains a component


And this international radiator has an Industry Canada ID: IC


of this device is subject to two conditions:
(1) This device may not cause harmful interference; and
(2) This device must accept any interference received, including
interference that may cause undesirable operation.
And this device meets the applicable Industry Canada technical



calling 617-951-0200. (www.silabs.com)

Manufacturing, L.P., and may be contacted by calling (713)-
816-2500, or at 19001 Kermier Rd., Waller TX 77484. (www.
)


less the 20cm during normal operations.
Table of Contents
1 Important Safety Instructions 2
2 Shipping Inspection 3
3 Codes & Regulations 3
4 Replacement Parts 3
5 Pre-Installation Considerations 3
6 Installation Location 3
7 Refrigerant Lines6
8 Condensate Drain Lines 9
9 Ductwork 10
10 Return Air Filters 10

Low Leakage Rate 10
12 Electric Heat 10
13 Electrical and Control Wiring 12
 13
15 Cool Cloud HVAC Phone Application 14

 14

 15
 16
19 Auxiliary Alarm Switch 17
20 Start-up Procedure17
21 Accessories 17
 18
19
24 Electric Air Cleaning 20
 20
 20
 21
28 Air Handler Display 23
 26
30 Wiring Diagram27
 30





























Questions and Answers

  • A
    Austin LeonardAug 19, 2025
    Why is my Goodman Air Handler not blowing air?
    • C
      cmyersAug 19, 2025
      Your Goodman Air Handler might not be operating due to several reasons: * A blockage in the circulator blower housing. * Seized circulator blower motor bearings. * A failed circulator blower motor. Check for obstructions in the circulator blower, and inspect the motor shaft rotation. If necessary, remove and repair/replace the wheel/motor.
  • R
    Robert GarzaAug 21, 2025
    What to do if Goodman Air Handler is not working?
    • Q
      qjenningsAug 21, 2025
      If your Goodman Air Handler isn't working, it could be due to abnormal motor loading, a sudden change in speed or torque, or a blockage of the air inlet or outlet. Check the filters, filter grills/registers, duct system, and air handler inlet/outlet for any blockages.
  • T
    Tyler CooperAug 23, 2025
    Why my Goodman Air Handler is not working?
    • J
      jeffery98Aug 23, 2025
      Your Goodman Air Handler may not be working due to loose or disconnected wiring at the circulator motor power leads. It could also be due to an open circuit or loose wiring at the inductor (3/4 Hp and 1 Hp models only), or a failed circulator blower motor. Ensure wiring connections are tightened or corrected. Verify the circuit through the inductor, replacing it if open or short. Check the circulator blower motor.
  • W
    wilsonnoahAug 26, 2025
    How to troubleshoot Goodman Air Handler with no operation?
    • E
      eyoungAug 26, 2025
      If your Goodman Air Handler has no operation, it might be caused by high or low AC line voltage. Also high ambient temperatures could be the reason. Check the power to the air handler and verify the line voltage is within the specified range on the rating plate.
  • A
    Amanda NguyenAug 28, 2025
    What to do if my Goodman Air Handler isn't operating?
    • E
      Eric GarciaAug 28, 2025
      If your Goodman Air Handler isn't operating, it could be due to loose wiring at the circulator motor control leads, a failed circulator blower motor, or a failed integrated control module. Tighten or correct the wiring connections. Check the circulator blower motor and integrated control module, replacing them if necessary.
  • A
    angelapetersonAug 30, 2025
    Why is my Goodman Air Handler not turning on?
    • B
      Benjamin JonesAug 30, 2025
      If your Goodman Air Handler isn't turning on, it may be due to a short in the low voltage wiring. Locate and correct the short in the low voltage wiring.
  • H
    Hannah EwingSep 2, 2025
    Why won't my Goodman outdoor unit turn on?
    • J
      Jennifer WaltersSep 2, 2025
      If your Goodman outdoor unit isn't operating, it could be due to improper low voltage wiring between the indoor and outdoor unit, or the outdoor control board lost power during operation. Locate and correct any improper low voltage wiring issues. Identify the reason the outdoor control board lost power.
  • A
    Alisha WilliamsSep 4, 2025
    What to do if Goodman Air Handler has no operation?
    • A
      Amanda AndersonSep 4, 2025
      If your Goodman Air Handler has no operation, check the evaporator drain pan, trap, and piping, as the issue might be a high water level in the evaporation coil or a short in the low voltage wiring. Also, replace the fuse with a 3-amp automotive type.
  • D
    Donna HaynesSep 6, 2025
    What causes a Goodman Air Handler to have reduced airflow?
    • K
      Kelly HawkinsSep 6, 2025
      Reduced airflow in your Goodman Air Handler can stem from blocked filters, restrictive or undersized ductwork, or high ambient temperatures. Check filters for blockage, clean them, or remove any obstructions. Inspect ductwork for blockages, remove obstructions, and ensure all registers are fully open. Verify the ductwork is appropriately sized for the system and resize or replace as needed.
  • A
    Alexander WheelerSep 8, 2025
    How to fix Goodman Air Handler operating at reduced performance?
    • D
      danielle57Sep 8, 2025
      If your Goodman Air Handler operates at reduced performance or on low stage when high stage is expected, the issue might be blocked filters or restrictive ductwork. Check the filters for blockage, cleaning them or removing any obstruction. Inspect the ductwork for blockage, remove any obstructions and verify all registers are fully open. Verify the ductwork is appropriately sized for the system and resize or replace the ductwork if necessary.

Summary

Introduction and Safety Overview

Installer Guidance and Warnings

Essential instructions and warnings for installation personnel.

1 Important Safety Instructions

General Safety Guidelines

Key safety warnings and cautions for operation and maintenance.

Carbon Monoxide Hazard

Warning about CO poisoning risks in enclosed areas.

2 Shipping, Codes, Parts, and Pre-Installation

6 Installation Location

7 Refrigerant Lines

Tubing Size and Preparation

Guidelines for selecting and preparing refrigerant tubing.

8 Condensate Drain Lines

9 Ductwork

System Ductwork Requirements

Guidelines for sizing and installing supply and return ductwork.

11 Airflow Leakage and Electric Heat

Electric Heat Kit Installation

Procedures for installing compatible electric heat kits.

13 Electrical and Control Wiring

Building Electrical Service Inspection

Inspection of building electrical service for compatibility.

Wire Sizing and Connections

Proper wire sizing and electrical connection methods.

Electrical Connections and Wiring

How to connect supply voltage and heat kits.

14 AVPTC Motor Orientation

16 Quick Start Guide for Non-Communicating Outdoor Units

18 Dehumidification Control Options

20 Start-Up Procedure

26 Regular Maintenance

27 Air Handler Troubleshooting Matrix

Troubleshooting Common Issues

Diagnosis and correction of common operational faults.

Troubleshooting Blower and Airflow Issues

Diagnosis of blower motor and airflow related problems.

30 Wiring Diagrams

Indoor Unit Wiring

Wiring diagram for the indoor unit and its components.

Electrical Connection Notes

Essential notes for making electrical connections.

Heater Kit Wiring

Wiring diagram for optional heater kit installations.

31 Start-up Checklist

Electrical and Static Pressure Checks

Checklist for electrical and static pressure measurements.

Goodman AVPTC37C14 Specifications

General IconGeneral
ModelAVPTC37C14
TypeAir Handler
RefrigerantR-410A
Nominal Airflow1200 CFM
Motor TypeECM
Voltage208/230V
Phase1
Maximum External Static Pressure0.8 in. W.C.
Width21 in.
Weight130 lbs
Cooling Capacity3 Tons

Related product manuals