AVPTC**14** AIR HANDLERS


© 2018-2021, 2023
Daikin Comfort Technologies Manufacturing, L.P.
19001 Kermier Rd., Waller, TX 77484
www.goodmanmfg.com - or - www.amana-hac.com
P/N: IOA-4030H Date: April 2023
is a registered trademark of Maytag Corporation or its related companies and is used under license. All rights reserved.

Prior to installation, thoroughly familiarize yourself with this Installation
Manual. Observe all safety warnings. During installation or repair,
caution is to be observed. It is your responsibility to install the product
safely and to educate the customer on its safe use.


This device, which was assembled by Daikin Comfort
Technologies Manufacturing, L.P., contains a component


And this international radiator has an Industry Canada ID: IC


of this device is subject to two conditions:
(1) This device may not cause harmful interference; and
(2) This device must accept any interference received, including
interference that may cause undesirable operation.
And this device meets the applicable Industry Canada technical



calling 617-951-0200. (www.silabs.com)

Manufacturing, L.P., and may be contacted by calling (713)-
816-2500, or at 19001 Kermier Rd., Waller TX 77484. (www.
)


less the 20cm during normal operations.
Table of Contents
1 Important Safety Instructions 2
2 Shipping Inspection 3
3 Codes & Regulations 3
4 Replacement Parts 3
5 Pre-Installation Considerations 3
6 Installation Location 3
7 Refrigerant Lines6
8 Condensate Drain Lines 9
9 Ductwork 10
10 Return Air Filters 10

Low Leakage Rate 10
12 Electric Heat 10
13 Electrical and Control Wiring 12
 13
15 Cool Cloud HVAC Phone Application 14

 14

 15
 16
19 Auxiliary Alarm Switch 17
20 Start-up Procedure17
21 Accessories 17
 18
19
24 Electric Air Cleaning 20
 20
 20
 21
28 Air Handler Display 23
 26
30 Wiring Diagram27
 30





























Questions and Answers

  • Z
    ztorresAug 19, 2025
    Why is my Goodman Air Handler not blowing air?
    • B
      Brian ButlerAug 19, 2025
      Your Goodman Air Handler might not be operating due to several reasons: * A blockage in the circulator blower housing. * Seized circulator blower motor bearings. * A failed circulator blower motor. Check for obstructions in the circulator blower, and inspect the motor shaft rotation. If necessary, remove and repair/replace the wheel/motor.
  • S
    Susan RyanAug 21, 2025
    What to do if Goodman Air Handler is not working?
    • J
      James SimmonsAug 21, 2025
      If your Goodman Air Handler isn't working, it could be due to abnormal motor loading, a sudden change in speed or torque, or a blockage of the air inlet or outlet. Check the filters, filter grills/registers, duct system, and air handler inlet/outlet for any blockages.
  • C
    Chad VanceAug 23, 2025
    Why my Goodman Air Handler is not working?
    • K
      Kathy JenkinsAug 23, 2025
      Your Goodman Air Handler may not be working due to loose or disconnected wiring at the circulator motor power leads. It could also be due to an open circuit or loose wiring at the inductor (3/4 Hp and 1 Hp models only), or a failed circulator blower motor. Ensure wiring connections are tightened or corrected. Verify the circuit through the inductor, replacing it if open or short. Check the circulator blower motor.
  • P
    Pamela KempAug 26, 2025
    How to troubleshoot Goodman Air Handler with no operation?
    • J
      jessicagreenAug 27, 2025
      If your Goodman Air Handler has no operation, it might be caused by high or low AC line voltage. Also high ambient temperatures could be the reason. Check the power to the air handler and verify the line voltage is within the specified range on the rating plate.
  • D
    David GrantAug 28, 2025
    What to do if my Goodman Air Handler isn't operating?
    • L
      Lisa OconnellAug 28, 2025
      If your Goodman Air Handler isn't operating, it could be due to loose wiring at the circulator motor control leads, a failed circulator blower motor, or a failed integrated control module. Tighten or correct the wiring connections. Check the circulator blower motor and integrated control module, replacing them if necessary.
  • B
    Billy WadeAug 30, 2025
    Why is my Goodman Air Handler not turning on?
    • S
      Scott GrahamAug 30, 2025
      If your Goodman Air Handler isn't turning on, it may be due to a short in the low voltage wiring. Locate and correct the short in the low voltage wiring.
  • M
    Michael ThorntonSep 2, 2025
    Why won't my Goodman outdoor unit turn on?
    • B
      Brittany GarciaSep 2, 2025
      If your Goodman outdoor unit isn't operating, it could be due to improper low voltage wiring between the indoor and outdoor unit, or the outdoor control board lost power during operation. Locate and correct any improper low voltage wiring issues. Identify the reason the outdoor control board lost power.
  • S
    sergiokingSep 4, 2025
    What to do if Goodman Air Handler has no operation?
    • S
      Scott RichardsSep 4, 2025
      If your Goodman Air Handler has no operation, check the evaporator drain pan, trap, and piping, as the issue might be a high water level in the evaporation coil or a short in the low voltage wiring. Also, replace the fuse with a 3-amp automotive type.
  • R
    Richard LongSep 6, 2025
    What causes a Goodman Air Handler to have reduced airflow?
    • M
      martinezreneeSep 6, 2025
      Reduced airflow in your Goodman Air Handler can stem from blocked filters, restrictive or undersized ductwork, or high ambient temperatures. Check filters for blockage, clean them, or remove any obstructions. Inspect ductwork for blockages, remove obstructions, and ensure all registers are fully open. Verify the ductwork is appropriately sized for the system and resize or replace as needed.
  • M
    mriceSep 9, 2025
    How to fix Goodman Air Handler operating at reduced performance?
    • L
      Linda GarnerSep 9, 2025
      If your Goodman Air Handler operates at reduced performance or on low stage when high stage is expected, the issue might be blocked filters or restrictive ductwork. Check the filters for blockage, cleaning them or removing any obstruction. Inspect the ductwork for blockage, remove any obstructions and verify all registers are fully open. Verify the ductwork is appropriately sized for the system and resize or replace the ductwork if necessary.

Summary

Safety and Installation Overview

Attention Installing Personnel

Instructions for installers regarding safety awareness and understanding the manual.

Important Safety Instructions

Critical safety warnings including fire, electrical shock, and carbon monoxide hazards.

Installation Preparation and Procedures

Shipping, Codes, and Pre-Installation

Procedures for inspection, codes, parts, and initial preparation before installation.

Installation Location and Configurations

Guidelines for site selection, clearances, and unit orientations (upflow, downflow, horizontal).

Refrigerant Lines and Condensate Drains

Instructions for refrigerant lines, tubing, TXV adjustments, and condensate drain installation.

Ductwork, Airflow, and Electric Heat

Requirements for ductwork, air filters, airflow leakage, and electric heat kit installation.

Electrical and Control Systems

Electrical Wiring and Connections

Procedures for electrical inspection, wire sizing, connections, grounding, and motor orientation.

Smart Features and Outdoor Unit Setup

Using the Cool Cloud app, and setting up communicating/non-communicating outdoor units.

Dehumidification, Accessories, and Ramping

Controls for dehumidification, accessories, and fan ramping profiles.

Operation, Troubleshooting, and Maintenance

Start-Up Procedures and Alarms

Steps for initial unit startup, alarm functions, and electric air cleaner warnings.

Troubleshooting Matrix and Display

Diagnosing faults using the matrix and understanding the air handler's LED display.

Airflow and Maintenance Recommendations

Information on airflow settings, labels, and routine homeowner maintenance.

Wiring Diagrams and Start-up Checklist

Detailed wiring diagrams and a checklist for verifying installation parameters.

Goodman AVPTC 14 Series Specifications

General IconGeneral
TypeAir Handler
RefrigerantR-410A
DimensionsVaries by model
WeightVaries by model
Cooling Capacity1.5 to 5 tons
Warranty10-year Parts
ConfigurationUpflow, Horizontal
Cabinet TypeGalvanized Steel
Voltage208/230V
CabinetHeavy-Gauge Steel