SS-DSXC16 www.goodmanmfg.com 29
Product SPecificationS
AHRI RAtIngs (cont.)
Outdoor
Unit
Indoor Units Cooling Ratings
CFM AHRI #
Coils/Air Handlers Furnaces Total¹ Sens.¹ SEER² EER³
DSXC16
0601B*
(cont.)
CA*F4961*6D*+TXV G*VM960805DXB* 56,000 41,500 15.50 12.30 1,575 5620804
CA*F4961*6D*+TXV A*VM961005DXB* 56,000 41,500 15.50 12.00 1,575 5620809
CA*F4961*6D*+TXV G*VM961005DXB* 56,000 41,500 15.50 12.00 1,575 5620810
CA*F4961*6D*+TXV A*VM961155DXB* 56,000 41,500 15.50 12.00 1,575 5620815
CA*F4961*6D*+TXV G*VM961155DXB* 56,000 41,500 15.50 12.00 1,575 5620816
CHPF4860D6D*+EEP+TXV 56,000 41,500 14.00 11.80 1,550 5357208
CHPF4860D6D*+MBVC2000**-1A*+TXV 57,000 42,500 15.50 12.30 1,800 3798903
CHPF4860D6D*+TXV A*VC81005C*B* 56,000 41,500 15.50 12.00 1,610 5038967
CHPF4860D6D*+TXV G*VC80805C*B* 56,000 41,500 15.50 12.30 1,590 5039014
CHPF4860D6D*+TXV A*VC80805C*B* 56,000 41,500 15.50 12.30 1,590 5039106
CHPF4860D6D*+TXV G*VC81005C*B* 56,000 41,500 15.50 12.00 1,610 5039117
CHPF4860D6D*+TXV A*VC950905CXB* 56,000 41,500 15.50 11.50 1,575 5620777
CHPF4860D6D*+TXV G*VC950905CXB* 56,000 41,500 15.50 11.50 1,575 5620778
CHPF4860D6D*+TXV A*VC950905DXB* 56,000 41,500 15.50 12.30 1,575 5620783
CHPF4860D6D*+TXV G*VC950905DXB* 56,000 41,500 15.50 12.30 1,575 5620784
CHPF4860D6D*+TXV A*VC951155DXB* 56,000 41,500 15.50 12.00 1,575 5620793
CHPF4860D6D*+TXV G*VC951155DXB* 56,000 41,500 15.50 12.00 1,575 5620794
CHPF4860D6D*+TXV A*VM960805CXB* 56,000 41,500 15.50 11.50 1,575 5620799
CHPF4860D6D*+TXV G*VM960805CXB* 56,000 41,500 15.50 11.50 1,575 5620800
CHPF4860D6D*+TXV A*VM960805DXB* 56,000 41,500 15.50 11.50 1,575 5620805
CHPF4860D6D*+TXV G*VM960805DXB* 56,000 41,500 15.50 11.50 1,575 5620806
CHPF4860D6D*+TXV A*VM961005DXB* 56,000 41,500 15.50 12.00 1,575 5620811
CHPF4860D6D*+TXV G*VM961005DXB* 56,000 41,500 15.50 12.00 1,575 5620812
CHPF4860D6D*+TXV A*VM961155DXB* 56,000 41,500 15.50 12.00 1,575 5620817
CHPF4860D6D*+TXV G*VM961155DXB* 56,000 41,500 15.50 12.00 1,575 5620818
CSCF4860N6D*+EEP+TXV 56,000 41,500 14.00 11.80 1,550 5357209
¹ BTU/h
² Seasonal Energy Eciency Rao; Cered per AHRI 210/240 @ 80°F/ 67°F/ 95°F
³ Energy Eciency Rao @ 80°F/ 67°F/ 95°F
Notes
Always check the S&R plate for electrical data on the unit being installed.
When matching the outdoor unit to the indoor unit, use the piston supplied with the out-
door unit or that specied on the piston kit chart supplied with the indoor unit.
EEP - Order from Service Dept. Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not in-
terchangeable with B13707-35S. The Goodman Gas Furnace contains the EEP cooling me delay

Questions and Answers: