INSTALLATION & OPERATING
INSTRUCTIONS
for GMPN
CONDENSING GAS FURNACE
(CATEGORY IV)
(U.S. PAT. # 5,437,263)
WARNING
IF THIS FURNACE IS INSTALLED IN AN ENCLOSED AREA, SUCH AS A GARAGE OR
UTILITY ROOM, EITHER ALONE OR WITH ANY OTHER CARBON MONOXIDE PRODUCING
DEVICE (i.e. ATUOMOBLIE, SPACE HEATER, WATER HEATER, ETC.) INSURE THAT THE
ENCLOSED AREA IS PROPERLY VENTILATED.
WARNING
CARBON MONOXIDE (REFERRED TO AS CO) CAN CAUSE SERIOUS PERSONAL INJURY
OR DEATH.
WARNING
THIS FURNACE IS DESIGN CERTIFIED FOR INSTALLATION IN BUILDINGS CONSTRUCTED
ON SITE ONLY.
Goodman Manufacturing Company, L.P.
IO-151D 1501 Seamist, Houston, Texas 77008 12/01
REPLACEMENT PARTS
Question and Answer IconNeed help?

Do you have a question about the Goodman GMPN and is the answer not in the manual?

Goodman GMPN Specifications

General IconGeneral
BrandGoodman
ModelGMPN
CategoryFurnace
LanguageEnglish

Summary

General Information

Installation

Installation instructions for the furnace in the USA and Canada, referencing codes and standards.

Location

Guidance on the proper placement of the furnace, avoiding unsuitable areas and ensuring protection.

Minimum Clearances to Combustible Surfaces

Specifies required distances from the furnace to combustible materials for safety and service access.

Venting

Critical information for the safe and proper installation of the furnace venting system.

Protection From Freezing

Details on protecting the vent pipe and drain assembly from freezing in unheated spaces.

Supporting and Pitching the Vent

Instructions on how to properly support and pitch horizontal vent pipes for condensate flow and safety.

Joining Pipe and Fittings

Guidelines and cautions for connecting vent pipes and fittings, emphasizing correct assembly methods.

Condensate Drain

Explanation of the condensate removal system for this condensing furnace and its requirements.

Gas Piping & Gas Pipe Capacity Table

Information on gas pipe sizing, capacity, and installation requirements for safe gas supply.

Circulating Air Supply and Return Air

Details on how to connect the furnace to the building's air supply and return air systems.

Electrical Supply Connections

Requirements for the electrical connection, including supply line, overload device, and wiring.

Control Voltage Connections

Instructions for making control voltage connections, including thermostat wiring.

Rating the Furnace

Information on furnace input rating, altitude adjustments, and gas type considerations.

Timing the Gas Meter

Procedure for determining the furnace's firing rate by timing the gas meter.

Main Burner Adjustment

Guidance on adjusting the main burners, including air shutter settings for proper flame appearance.

Safety Control Functions and Check-out Procedure

Main Limit Switch

Details on the function and testing of the main limit switch for over-temperature protection.

Blower Door Interlock Switch

Explains the blower door interlock switch and its role in preventing operation without the door secured.

Flame Roll-out Switch

Information on the flame roll-out switches, their function, and testing procedures.

Integrated Fan / Ignition Control

Circulating Air Filters

Importance of clean filters, inspection frequency, and minimum filter sizes for furnace operation.

Temperature Rise

Procedure for measuring and adjusting the furnace's temperature rise for optimal performance.

Motor Lubrication and Maintenance

Service Instructions

General service recommendations for efficient and safe operation of the heating system.

Sequence of Operation

Detailed description of the furnace's operational sequence in heating and cooling modes, including lockout conditions.

Removing an Existing Appliance

Inspecting & Cleaning the Heat Exchanger

Instructions for annual inspection and cleaning of the heat exchanger for optimal performance and longevity.

Source of Combustion Air

Blower Off Delay

Explanation of the blower off delay feature and how to adjust its timing.

Electronic Air Cleaner Control

Humidifier Control

Details on connecting a humidistat to the furnace control for humidity management.

Drain Connections

Lighting Instructions

For Your Safety Read Before Operating

Critical safety warnings to be read and followed before operating the furnace.

Operating Instructions

Step-by-step guide for safely starting and operating the furnace.