product speciFications
gMVc95 airFlow speciFications
HigH- or single-stage cooling speeds
GMVC950453BXAA GMVC950704CXAA GMVC950905DXAA GMVC951155DXAA
Cooling
Speed Tap
Adjust
Tap
CFM
1
Cooling
Speed Tap
Adjust
Tap
CFM
1
Cooling
Speed Tap
Adjust
Tap
CFM
1
Cooling
Speed Tap
Adjust
Tap
CFM
1
A
Minus (-) 585
A
Minus (-) 585
A
Minus (-) 720
A
Minus (-) 720
Normal 650 Normal 650 Normal 800 Normal 800
Plus (+) 715 Plus (+) 715 Plus (+) 880 Plus (+) 880
B
Minus (-) 810
B
Minus (-) 810
B
Minus (-) 945
B
Minus (-) 945
Normal 900 Normal 900 Normal 1050 Normal 1050
Plus (+) 990 Plus (+) 990 Plus (+) 1155 Plus (+) 1155
C
Minus (-) 990
C
Minus (-) 1195
C
Minus (-) 1305
C
Minus (-) 1305
Normal 1100 Normal 1325 Normal 1450 Normal 1450
Plus (+) 1210 Plus (+) 1460 Plus (+) 1595 Plus (+) 1595
D
Minus (-) 1080
D
Minus (-) 1440
D
Minus (-) 1800
D
Minus (-) 1800
Normal 1200 Normal 1600 Normal 2000 Normal 2000
Plus (+) 1320 Plus (+) 1760 Plus (+) 2200 Plus (+) 2200
¹ @ .1” to .8” W.C. ESP
Notes:
• All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
• For most jobs, about 400 CFM per ton when cooling is desirable.
• Do not operate above .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.
low-stage cooling speeds
GMVC950453BXAA GMVC950704CXAA GMVC950905DXAA GMVC951155DXAA
Cooling
Speed Tap
Adjust
Tap
CFM
1
Cooling
Speed Tap
Adjust
Tap
CFM
1
Cooling
Speed Tap
Adjust
Tap
CFM
1
Cooling
Speed Tap
Adjust
Tap
CFM
1
A
Minus (-) 390
A
Minus (-) 390
A
Minus (-) 480
A
Minus (-) 480
Normal 435 Normal 435 Normal 535 Normal 535
Plus (+) 480 Plus (+) 480 Plus (+) 590 Plus (+) 590
B
Minus (-) 545
B
Minus (-) 545
B
Minus (-) 635
B
Minus (-) 635
Normal 605 Normal 605 Normal 705 Normal 705
Plus (+) 665 Plus (+) 665 Plus (+) 775 Plus (+) 775
C
Minus (-) 665
C
Minus (-) 800
C
Minus (-) 875
C
Minus (-) 875
Normal 735 Normal 890 Normal 970 Normal 970
Plus (+) 810 Plus (+) 975 Plus (+) 1070 Plus (+) 1070
D
Minus (-) 725
D
Minus (-) 965
D
Minus (-) 1205
D
Minus (-) 1205
Normal 805 Normal 1070 Normal 1340 Normal 1340
Plus (+) 885 Plus (+) 1180 Plus (+) 1475 Plus (+) 1475
¹ @ .1” to .8” W.C. ESP
Notes:
• All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
• For most jobs, about 400 CFM per ton when cooling is desirable.
• Do not operate above .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.