10
COOLING PERFORMANCE DATA
GSC130181A*
EXPANDED PERFORMANCE DATA COOLING OPERATION
MODEL: GSC130181A* / CAUF1824A6A
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Tem perature
IDB*Airflow 596367715963677159636771596367715963677159636771
MBh 18.6 19.3 21.1 - 18.2 18.8 20.7 - 17.8 18.4 20.2 - 17.3 18.0 19.7 - 16.5 17.1 18.7 - 15.2 15.8 17.3 -
S/T 0.71 0.59 0.41 - 0.73 0.61 0.43 - 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.81 0.67 0.47 - 0.81 0.68 0.47 -
Delta T 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
675 KW 1.38 1.40 1.44 - 1.47 1.49 1.53 - 1.54 1.57 1.61 - 1.60 1.63 1.68 - 1.66 1.69 1.74 - 1.71 1.74 1.79 -
AMPS 4.4 4.5 4.6 - 4.7 4.8 5.0 - 5.1 5.2 5.4 - 5.4 5.6 5.7 - 5.8 5.9 6.1 - 6.1 6.3 6.5 -
HI PR 137 148 156 - 154 166 175 - 175 189 199 - 200 215 227 - 225 242 255 - 248 267 282 -
LO PR 62 66 72 - 66 70 76 - 68 73 79 - 72 76 83 - 75 80 87 - 78 83 90 -
MBh 18.1 18.7 20.5 - 17.7 18.3 20.0 - 17.2 17.9 19.6 - 16.8 17.4 19.1 - 16.0 16.6 18.1 - 14.8 15.3 16.8 -
S/T 0.68 0.56 0.39 - 0.70 0.59 0.41 - 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.77 0.64 0.45 - 0.78 0.65 0.45 -
Delta T 19 16 12 - 19 16 12 - 19 16 12 - 19 17 13 - 19 16 12 - 18 15 12 -
70 600 KW 1.37 1.40 1.43 - 1.46 1.48 1.52 - 1.53 1.56 1.60 - 1.59 1.62 1.67 - 1.65 1.68 1.72 - 1.70 1.73 1.77 -
AMPS 4.3 4.4 4.6 - 4.7 4.8 4.9 - 5.0 5.2 5.3 - 5.4 5.5 5.7 - 5.7 5.9 6.0 - 6.1 6.2 6.4 -
HI PR 136 146 155 - 153 164 173 - 174 187 197 - 198 213 225 - 222 239 253 - 246 264 279 -
LO PR 62 65 71 - 65 69 75 - 68 72 78 - 71 75 82 - 74 79 86 - 77 82 89 -
MBh 16.7 17.3 18.9 - 16.3 16.9 18.5 - 15.9 16.5 18.1 - 15.5 16.1 17.6 - 14.7 15.3 16.7 - 13.7 14.2 15.5 -
S/T 0.65 0.54 0.38 - 0.68 0.56 0.39 - 0.69 0.58 0.40 - 0.72 0.60 0.41 - 0.74 0.62 0.43 - 0.75 0.63 0.43 -
Delta T 19 16 13 - 19 17 13 - 19 17 13 - 19 17 13 - 19 17 13 - 18 16 12 -
525 KW 1.35 1.37 1.40 - 1.43 1.45 1.49 - 1.50 1.52 1.56 - 1.56 1.59 1.63 - 1.61 1.64 1.69 - 1.66 1.69 1.74 -
AMPS 4.2 4.3 4.4 - 4.5 4.6 4.8 - 4.9 5.0 5.2 - 5.2 5.4 5.5 - 5.6 5.7 5.9 - 5.9 6.0 6.2 -
HI PR 132 142 150 - 148 159 168 - 168 181 191 - 192 206 218 - 216 232 245 - 238 257 271 -
LO PR 60 63 69 - 63 67 73 - 66 70 76 - 69 73 80 - 72 77 84 - 75 79 87 -
MBh 18.9 19.5 21.1 22.6 18.5 19.0 20.6 22.1 18.1 18.6 20.1 21.6 17.6 18.1 19.6 21.1 16.7 17.2 18.6 20.0 15.5 16.0 17.3 18.5
S/T 0.81 0.72 0.55 0.35 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.37 0.88 0.79 0.60 0.39 0.92 0.82 0.62 0.40 0.93 0.83 0.63 0.40
Delta T2119161121191611211916112120 16 11 21 19 16 11 20 18 15 10
675 KW 1.39 1.41 1.45 1.49 1.47 1.50 1.54 1.58 1.55 1.58 1.62 1.66 1.62 1.64 1.69 1.74 1.67 1.70 1.75 1.80 1.72 1.75 1.80 1.85
AMPS4.44.54.64.84.74.85.05.25.15.35.45.65.55.6 5.8 6.0 5.8 6.0 6.2 6.4 6.2 6.3 6.5 6.8
HI PR 139 149 158 164 156 168 177 185 177 191 201 210 202 217 229 239 227 244 258 269 251 270 285 297
LO PR 63 67 73 78 66 71 77 82 69 73 80 85 72 77 84 90 76 81 88 94 78 83 91 97
MBh 18.4 18.9 20.5 22.0 18.0 18.5 20.0 21.5 17.5 18.0 19.5 21.0 17.1 17.6 19.1 20.5 16.2 16.7 18.1 19.4 15.0 15.5 16.8 18.0
S/T 0.77 0.69 0.52 0.33 0.80 0.71 0.54 0.35 0.82 0.73 0.55 0.36 0.84 0.75 0.57 0.37 0.88 0.78 0.59 0.38 0.88 0.79 0.60 0.38
Delta T2220161122201711222017112220 17 12 22 20 16 11 20 19 15 11
75 600 KW 1.38 1.40 1.44 1.48 1.47 1.49 1.53 1.57 1.54 1.57 1.61 1.65 1.60 1.63 1.68 1.72 1.66 1.69 1.74 1.78 1.71 1.74 1.79 1.84
AMPS4.44.54.64.84.74.85.05.15.15.25.45.65.45.6 5.7 6.0 5.8 5.9 6.1 6.3 6.1 6.3 6.5 6.7
HI PR 137 148 156 163 154 166 175 183 175 189 199 208 200 215 227 237 225 242 255 266 248 267 282 294
LO PR 62 66 72 77 66 70 76 81 68 73 79 84 72 76 83 89 75 80 87 93 78 83 90 96
MBh 17.0 17.5 18.9 20.3 16.6 17.1 18.5 19.8 16.2 16.7 18.0 19.4 15.8 16.3 17.6 18.9 15.0 15.4 16.7 17.9 13.9 14.3 15.5 16.6
S/T 0.74 0.66 0.50 0.32 0.77 0.69 0.52 0.33 0.79 0.70 0.53 0.34 0.81 0.73 0.55 0.35 0.84 0.75 0.57 0.37 0.85 0.76 0.58 0.37
Delta T2220171122211712222117122221 17 12 22 20 17 12 21 19 16 11
525 KW 1.36 1.38 1.41 1.45 1.44 1.46 1.50 1.54 1.51 1.53 1.58 1.62 1.57 1.60 1.64 1.69 1.63 1.65 1.70 1.75 1.67 1.70 1.75 1.80
AMPS4.24.34.54.64.64.74.85.05.05.15.25.45.35.4 5.6 5.8 5.6 5.7 5.9 6.2 5.9 6.1 6.3 6.5
HI PR 133 143 151 158 150 161 170 177 170 183 193 202 194 208 220 230 218 235 248 258 241 259 274 285
LO PR 60 64 70 75 64 68 74 79 66 70 77 82 70 74 81 86 73 78 85 90 75 80 88 93
* Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions