EasyManua.ls Logo

Goodman GSZ11 - User Manual

Goodman GSZ11
9 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
REPAIR PARTS
RP
-
636
This manual is to be used by qualified technicians only.
www.amana-hac.com
© 2009 Goodman Manufacturing Company, L.P. 5151 San Felipe, Suite 500 Houston, TX 77056
February 2011
GSZ11 Remote Heat Pumps
GSZ110903AA
GSZ110904AA
GSZ111203AA
GSZ111204AA
Question and Answer IconNeed help?

Do you have a question about the Goodman GSZ11 and is the answer not in the manual?

Summary

Important Information

Index

Table of contents for document sections including parts lists and illustrations.

Functional Parts List

List of functional components and their associated part numbers.

Illustration and Parts

References to diagrams illustrating component placement and part identification.

Functional Parts

SPECIAL PARTS

Section detailing specific or non-standard components.

Expanded Model Nomenclature

Explanation of model codes and their corresponding product identifiers.

Control Cover; Control Box

Expanded Model Nomenclature

Explanation of model codes and their corresponding product identifiers.

Compressor; Tubing Assembly

Expanded Model Nomenclature

Explanation of model codes and their corresponding product identifiers.

Coil; Cabinet Top; Side Panels

Expanded Model Nomenclature

Explanation of model codes and their corresponding product identifiers.

Summary

Important Information

Index

Table of contents for document sections including parts lists and illustrations.

Functional Parts List

List of functional components and their associated part numbers.

Illustration and Parts

References to diagrams illustrating component placement and part identification.

Functional Parts

SPECIAL PARTS

Section detailing specific or non-standard components.

Expanded Model Nomenclature

Explanation of model codes and their corresponding product identifiers.

Control Cover; Control Box

Expanded Model Nomenclature

Explanation of model codes and their corresponding product identifiers.

Compressor; Tubing Assembly

Expanded Model Nomenclature

Explanation of model codes and their corresponding product identifiers.

Coil; Cabinet Top; Side Panels

Expanded Model Nomenclature

Explanation of model codes and their corresponding product identifiers.

Overview

The GSZ11 Remote Heat Pump is a residential or light commercial heating and cooling system designed for outdoor installation. It operates as a split system, meaning it works in conjunction with an indoor coil and furnace or air handler to provide year-round comfort. The unit is specifically designed to use R410A refrigerant, a common and environmentally friendly hydrofluorocarbon (HFC) refrigerant. This necessitates the use of approved equipment and adherence to specific service procedures for any sealed system work, as detailed in the accompanying Service Manual or Installation Instructions.

Functional Description:

The GSZ11 functions as a heat pump, capable of both heating and cooling a space. In cooling mode, it extracts heat from the indoor air and expels it outdoors. In heating mode, it reverses the process, extracting heat from the outdoor air (even in cold conditions) and transferring it indoors. This dual functionality makes it an energy-efficient solution for climate control. The system incorporates a compressor, a condenser coil, a fan, and various control components to manage the refrigerant cycle.

Important Technical Specifications:

The GSZ11 series includes several models with varying capacities and electrical configurations, as indicated by their model numbers:

  • GSZ110903AA (M1): This model features an 83,000 BTU compressor (ZP83KCETF5250) operating on 200/230V, 60Hz, 3-phase power. It uses a 240V, 90W crankcase heater (0130L00020S) and a 20/370V capacitor (CAP200000440RPS). The condenser motor (0131M00040S) is 1 HP, 1-speed, 230V. The reversing valve (0151R00001P) is specific to this model and M2.
  • GSZ110904AA (M2): This model also has an 83,000 BTU compressor (ZP83KCETFD130) but operates on 460V, 60Hz, 3-phase power. It uses a 460V, 90W crankcase heater (0130L00021S) and the same 20/370V capacitor. The condenser motor (0131M00041S) is 1 HP, 1-speed, 460V. The reversing valve (0151R00001P) is shared with M1.
  • GSZ111203AA (M3): This higher-capacity model features a 105,000 BTU compressor (ZP103KCETF5155) operating on 200/230V, 60Hz, 3-phase power. It uses a 240V, 90W crankcase heater (0130L00020S) and the same 20/370V capacitor. The condenser motor (0131M00040S) is 1 HP, 1-speed, 230V. The reversing valve (0151R00000P) is specific to this model and M4.
  • GSZ111204AA (M4): The largest capacity model, this unit has a 105,000 BTU compressor (ZP103KCETFD250) operating on 460V, 60Hz, 3-phase power. It uses a 460V, 90W crankcase heater (0130L00021S) and the same 20/370V capacitor. The condenser motor (0131M00041S) is 1 HP, 1-speed, 460V. The reversing valve (0151R00000P) is shared with M3.

All models share common components such as a 24V relay (0130M00025S), a 40 AMP, 3P, 24V contactor (CONT3P040024VS), a defrost control board (PCBDM133), a defrost thermostat (B1370803), an expansion valve (0151R00029), and a 26-inch fan blade (B1086768). Safety features include high-pressure (0130M00089) and low-pressure (0130M00088) cutout switches. The unit's construction includes a 35-inch base pan (0121R00007PDG), a venturi top panel (0121R00013PDG), and louvered side panels (0121R00043PDGB, 0121R00047PDGB, 0121R00051PDG) for protection and airflow.

Usage Features:

The GSZ11 is designed for remote installation, typically outdoors on a concrete pad or similar stable surface. Its robust construction, including the louvered side panels and wire grill, protects internal components from environmental elements while allowing for proper airflow. The unit's operation is managed by a defrost control board, which intelligently initiates defrost cycles to prevent ice buildup on the outdoor coil during heating mode in cold weather, ensuring efficient operation. The inclusion of a crankcase heater helps prevent refrigerant migration to the compressor oil during off-cycles, which can lead to compressor damage upon startup. Service valves (1 1/8" and 5/8") are provided for easy connection to the refrigerant lines. An accumulator (B1226212) is integrated into the system to protect the compressor from liquid refrigerant slugging. A filter drier (B1219227) ensures the cleanliness and dryness of the refrigerant circuit.

Maintenance Features:

Maintenance of the GSZ11 heat pump should be performed by qualified technicians only, using authorized factory parts. The unit features a lower access panel (4400211PDG) and a control cover (0121R00053PDG) for easy access to electrical and control components during service. The defrost control board (PCBDM133) is a key component that can be replaced if diagnostic codes indicate a fault. The capacitor (CAP200000440RPS) and contactor (CONT3P040024VS) are also accessible for inspection and replacement. The fan motor and blade are designed for durability, but replacement parts are available if needed. Compressor grommets (0164M00018) and bolts (B1393740) are used for vibration isolation and can be replaced if wear or damage occurs. The filter drier (B1219227) is a consumable component that should be replaced whenever the sealed refrigerant system is opened for service. A sight glass (B1372801, NS) may be present on some units to allow technicians to visually inspect the refrigerant charge. For any warranty service or repairs after the warranty expires, Goodman Manufacturing Company, L.P. strongly recommends contacting an authorized technician and using genuine factory parts to ensure optimal performance and longevity of the unit. The manual provides contact information for consumer affairs and international divisions for assistance.

Goodman GSZ11 Specifications

General IconGeneral
BrandGoodman
ModelGSZ11
CategoryHeat Pump
LanguageEnglish