Questions and Answers

  • J
    John FloresAug 18, 2025
    What to do if my Goodwe GW25K-MT Inverter shows System Failure?
    • B
      Brittany JohnsonAug 18, 2025
      If your Goodwe Inverter is showing a System Failure, here are a few things you can check: 1. First, disconnect the DC switch and take off the DC connector. Then, check the impedance between PV (+) & PV (-) to earth. 2. If the impedance is less than 100 kΩ, check the insulation of the PV string wiring to the earth. 3. If the impedance is larger than 100 kΩ, check AC wiring after taking off the AC connector and measuring the impedance between neutral and PE. If it is larger than 10 kΩ, check AC wiring.
  • M
    Michael MartinAug 20, 2025
    What should I do if my Goodwe GW25K-MT Inverter has Utility Loss?
    • P
      parkerstevenAug 20, 2025
      If your Goodwe Inverter reports a Utility Loss, follow these steps: 1. Disconnect the DC switch and take off the AC connector. 2. Measure the voltage between line and neutral in the connector to ensure it conforms to the grid-connected specification of the inverter. 3. If it doesn't, check if the distribution switch is connected and the grid is normal. 4. If it does, reconnect the AC connector and DC connector.
  • F
    friceAug 23, 2025
    What to do if Goodwe GW25K-MT displays AC Voltage Failure?
    • M
      Monica SullivanAug 23, 2025
      If your Goodwe Inverter displays an AC Voltage Failure, here’s what you can do: 1. Disconnect the DC switch and take off the AC connector. 2. Measure the voltage between line and neutral in the connector to ensure it conforms to the grid-connected specification of the inverter. 3. If it doesn't, check the grid wiring. 4. If it does, connect the AC connector and reconnect the DC switch; the inverter will connect automatically.
  • E
    Erik WatkinsAug 26, 2025
    What to do if Goodwe Inverter shows Ground I Failure?
    • J
      jessicabergerAug 26, 2025
      If your Goodwe Inverter shows a Ground I Failure, try the following: 1. Disconnect the DC switch. 2. Check the insulation of the PV string wiring to earth. 3. Reconnect the DC switch again.
  • G
    Gina BlairAug 28, 2025
    What to do if my Goodwe GW25K-MT has AC Frequency Failure?
    • R
      rodgerskariAug 28, 2025
      If your Goodwe Inverter is experiencing an AC Frequency Failure, the PV inverter will automatically restart when the frequency returns to normal.
  • J
    Jerome HowellAug 30, 2025
    What to do if my Goodwe GW25K-MT Inverter is not displaying anything?
    • D
      Douglas JohnstonAug 30, 2025
      If your Goodwe Inverter has no display, take these steps: 1. Disconnect the DC switch and take off the DC connector. 2. Measure the voltage of the PV string. 3. Plug in the DC connector and reconnect the DC switch. 4. If the voltage is less than 70 V, check the PV string configuration.
  • E
    eugene82Sep 2, 2025
    What to do if my Goodwe GW25K-MT shows 'Vac Failure'?
    • A
      Ashley BallSep 2, 2025
      If your Goodwe Inverter displays a 'Vac Failure', the inverter will automatically restart within 5 minutes if the grid returns to normal. Also, ensure that the grid voltage conforms to the specifications and that the neutral (N) wire and PE wire are properly connected.
  • J
    joseph49Sep 4, 2025
    What should I do if my Goodwe GW25K-MT displays 'Utility Loss'?
    • R
      Ruben HillSep 5, 2025
      If your Goodwe Inverter is showing a 'Utility Loss' error, make sure that it is connected to the grid. Check if the power grid cable is connected and verify the availability of the power grid.
  • B
    bmannSep 7, 2025
    What does 'Fac Failure' mean on my Goodwe Inverter and how to fix it?
    • J
      Joshua SpencerSep 7, 2025
      If your Goodwe Inverter displays 'Fac Failure', it indicates that the grid is not connected. Check the grid connection cables and verify the availability of the grid.
  • J
    Jeffrey MasonSep 9, 2025
    What to do if Goodwe Inverter shows 'Ground I Failure'?
    • M
      Melanie SnyderSep 10, 2025
      If your Goodwe Inverter is showing a 'Ground I Failure', it means that the ground current is too high. Unplug the inputs from the PV generator and check the peripheral AC system. After clearing the problem, reconnect the PV panel and check the Inverter status.

Summary

About This Manual

Safety Precautions

General Safety Guidelines

Outlines overall safety rules for installation and operation.

DC Side Safety Measures

Specific safety instructions for the DC electrical connections.

AC Side Safety Measures

Safety guidelines for the AC electrical connections.

Inverter Installation Safety

Precautions to be taken during the physical installation of the inverter.

Personnel Safety Requirements

Qualifications and protective equipment needed for personnel.

Installation

Installation Environment Requirements

Specifies suitable locations and conditions for inverter installation.

Inverter Mounting and Installation

Step-by-step guide for physically installing the inverter.

Electrical Connection

Electrical Connection Safety

Critical safety rules for electrical wiring procedures.

PE Cable Connection

Instructions for correctly connecting the protective earth cable.

PV Input Cable Connection

Detailed steps for connecting the DC input cables from PV modules.

AC Output Cable Connection

Guidance on connecting the AC output cable to the grid.

Equipment Commissioning

System Commissioning

Maintenance

Troubleshooting Common Faults

Steps to diagnose and resolve typical inverter issues.