6. START-UP AND ADJUSTMENTS
Before its rst start-up. Running-in procedure
Perform this procedure before using the compressor for the rst time. Once completed, it does not need
to be repeated.
1. Attach the wheels and the support bracket (see previous point of assembly).
2. Make sure the compressor on/o switch is in the "О" o position.
3. Open the tank drain valve.
4. Check the correspondence between the data on the compressor nameplate with the actual
specications of the electrical system and plug the power cord into a suitable socket.
5. Set the on/o switch to the on position "I" and run the compressor for 30 minutes.
6. Return the switch to the o position "О".
7. Unplug the power cord.
8. Close the drain valve.
9. At this point, the compressor is ready for use.
Before each start-up. Operating procedure
1. Turn the pressure regulator fully counterclockwise to shut o the air ow.
2. Connect the air hose to the compressor air outlet quick coupling.
3. Set the on/o switch to the "О" o position.
4. Plug in the power cord.
5. Set the on/o switch to the on position "I" and let the compressor run until it reaches the automatic
cut-out pressure.
6. Connect the ination valve or pneumatic tool connection to the end of the hose.
7. Adjust the regulator to the proper pressure for the pneumatic tool.
WARNING:
READ THE AIR TOOL INSTRUCTION MANUAL BEFORE CONNECTING THE AIR TOOL TO THE COMPRESSOR.
8. To shut down set the switch to the "О" o position, unplug the power cord and empty the reservoir.
ATENTTION:
As the air in the tank is depleted by the use of any tool, the compressor will automatically restart at its
preset "on" pressure. When a tool is used continuously, the compressor will automatically turn on and off.