English • Owner´s manual
33
Compressor runs
continuously
Defective pressure switch. Replace the switch.
Excessive air demand.
Use tools sized to the ow rate that the
compressor can deliver.
Air leakage.
Check all connections with a soap and
water solution to see where the leak
can be found.
Compressor vibrates Loose mounting screws Tighten the screws
Lower than usual air
ow rate
Broken inlet valves.
Have the unit repaired by an authorized
service representative.
Dirty suction lter. Clean or replace the suction lter.
Leaking connections. Tighten connections.
ATTENTION: Do not make any modications to the machine that may damage its operation. Any
alterations or modications made will invalidate the product warranty.
If your device continues to give errors or presents any other type of problem, please contact our
technical service so that our team can advise you and solve the problem.
9. TECHNICAL DATA
MODEL GY08248SOF GY 08248SOFS GY 08248SOFH
Displacement Single cylinder
Voltage 230V / 50Hz 110V / 60Hz 220V / 60Hz
Engine type Brushless
Power 0,8 HP / 0,6 Kw 1 HP / 0,75 Kw 1 HP / 0,75 Kw
Working speed (rpm) 1450 rpm 1750 rpm 1750 rpm
Tank capacity 24 L
Air ow rate (l/min) 110 l/min aprox. 130 l/min aprox. 130 l/min aprox.
Nominal pressure (bar- PSI) 6 bar - 85 PSI
Max. pressure (bar- PSI) 8 bar - 115 PSI
Noise level 73 dB 78 dB 78 dB
Weight 20,6 kg 21 kg 21 kg