    alexanderpachecoAug 9, 2025
    What to do if my Goulds SJ10 delivers water but will not shut off?
    • W
      walshmichaelAug 9, 2025
      If your Goulds Water Pump delivers water but doesn't shut off, it could be due to a plugged or incorrectly adjusted pressure switch. In this case, you should clean and adjust the pressure switch. Another potential cause is a defective suction check or foot valve, which would require replacement.
  • M
    Matthew WilliamsAug 16, 2025
    Why is my Goulds Water Pump not running?
    • T
      Taylor KimAug 16, 2025
      If your Goulds Water Pump isn't running, there are several potential reasons. First, the motor thermal protector may have tripped; try resetting it. Second, check for an open circuit breaker or a blown fuse and replace them if necessary. Finally, the motor itself might be defective, requiring replacement.
  • C
    Chad EdwardsAug 25, 2025
    What to do if my Goulds Water Pump cycles excessively?
    • L
      Lydia ByrdAug 25, 2025
      If your Goulds Water Pump cycles excessively, it could be due to a water-logged pressure tank. Try draining and recharging the pressure tank. Another cause might be the pump being farther than 5 feet from the tank; move the pump closer. High friction loss valves between the pump and tank may also be the reason; replace them with fully open gate valves to reduce friction loss.
  • E
    Erika GreenAug 31, 2025
    How to fix little or no liquid delivered by Goulds SJ10 Water Pump?
    • M
      Michael BrooksAug 31, 2025
      If your Goulds Water Pump delivers little or no liquid, it could be due to several reasons. First, the pump might not be primed, the suction pipe submergence may be inadequate, or there could be an air leak in the suction pipe. Prime the pump and ensure the suction pipe is correctly submerged and free of leaks. Second, the discharge or suction may be plugged, or a valve may be closed; clear any blockages and ensure valves are open. Finally, the suction lift or suction losses may be excessive; reduce suction lift and minimize losses.

Summary

Safety Instructions and Warnings

Hazard Level Warnings

Details hazard levels (Danger, Warning, Caution) and important notices for safe operation.

Electrical Safety Guidelines

Ensures all electrical work is performed by qualified technicians following codes.

Installation Preparation Steps

Shallow Well Installation Procedures

Deep Well Twin Pipe Installation

Deep Well Packer System Installation

Deep Well Discharge Piping Requirements

Explains the need for back pressure and the use of pressure control valves for deep well systems.

Motor Power and Electrical Setup

Connecting Power Supply to Motor

Connect power supply wires to the pressure switch and verify motor voltage settings.

Motor Wiring and Connections

Connecting Power and Ground Wires

Connect power supply wires to pressure switch Line terminals and secure the ground wire.

Technical Data and Specifications

Voltage Change and Motor Wiring

Details voltage change procedures and terminal board designs for AO Smith/Century and Nidec motors.

Deep Well Jet Pump Technical Data

Shallow Well Jet Pump Technical Data

Troubleshooting Pump and Motor Issues

Motor and Pump Operation Problems

Addresses motor not running, pump cycling, and water delivery problems with probable causes.