  • A
    Anthony RobinsonAug 9, 2025
    What to do if my Goulds SJ15 delivers water but will not shut off?
    • D
      diane60Aug 9, 2025
      If your Goulds Water Pump delivers water but doesn't shut off, it could be due to a plugged or incorrectly adjusted pressure switch. In this case, you should clean and adjust the pressure switch. Another potential cause is a defective suction check or foot valve, which would require replacement.
  • J
    Julie HardyAug 17, 2025
    Why is my Goulds SJ15 Water Pump not running?
    • L
      Linda ValdezAug 17, 2025
      If your Goulds Water Pump isn't running, there are several potential reasons. First, the motor thermal protector may have tripped; try resetting it. Second, check for an open circuit breaker or a blown fuse and replace them if necessary. Finally, the motor itself might be defective, requiring replacement.
  • M
    mdurhamAug 25, 2025
    What to do if my Goulds SJ15 cycles excessively?
    • J
      Jeffrey RiceAug 25, 2025
      If your Goulds Water Pump cycles excessively, it could be due to a water-logged pressure tank. Try draining and recharging the pressure tank. Another cause might be the pump being farther than 5 feet from the tank; move the pump closer. High friction loss valves between the pump and tank may also be the reason; replace them with fully open gate valves to reduce friction loss.
  • R
    Regina ButlerAug 31, 2025
    How to fix little or no liquid delivered by Goulds SJ15 Water Pump?
    • C
      Cody WaltersAug 31, 2025
      If your Goulds Water Pump delivers little or no liquid, it could be due to several reasons. First, the pump might not be primed, the suction pipe submergence may be inadequate, or there could be an air leak in the suction pipe. Prime the pump and ensure the suction pipe is correctly submerged and free of leaks. Second, the discharge or suction may be plugged, or a valve may be closed; clear any blockages and ensure valves are open. Finally, the suction lift or suction losses may be excessive; reduce suction lift and minimize losses.

Summary

Selecting the Correct Jet Pump System

Preparing for Installation

Deep Well Twin Pipe

Deep Well Packer System

Priming a Shallow Well System

Priming a Deep Well System

Power the Motor

Booster Systems

Checking Suction Lift on a Shallow Well

Troubleshooting

Motor Not Running

Lists probable causes for the motor not running.

Little or No Liquid Delivered by Pump

Lists probable causes for low or no liquid delivery.

Pump Delivers Water - Will Not Shut Off

Lists probable causes for the pump not shutting off.

Pump Cycles Excessively

Lists probable causes for excessive pump cycling.