Jet Pumps
INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL
INSTRUCTION MANUAL
IM102R07

Table of Contents

Questions and Answers

  • T
    Todd RodriguezAug 9, 2025
    What to do if my Goulds Water Pump delivers water but will not shut off?
    • T
      Thomas TurnerAug 9, 2025
      If your Goulds Water Pump delivers water but doesn't shut off, it could be due to a plugged or incorrectly adjusted pressure switch. In this case, you should clean and adjust the pressure switch. Another potential cause is a defective suction check or foot valve, which would require replacement.
  • P
    phillAug 16, 2025
    Why is my Goulds J10 Water Pump not running?
    • P
      Philip NavarroAug 17, 2025
      If your Goulds Water Pump isn't running, there are several potential reasons. First, the motor thermal protector may have tripped; try resetting it. Second, check for an open circuit breaker or a blown fuse and replace them if necessary. Finally, the motor itself might be defective, requiring replacement.
  • A
    andreahobbsAug 25, 2025
    What to do if my Goulds Water Pump cycles excessively?
    • J
      jamie53Aug 25, 2025
      If your Goulds Water Pump cycles excessively, it could be due to a water-logged pressure tank. Try draining and recharging the pressure tank. Another cause might be the pump being farther than 5 feet from the tank; move the pump closer. High friction loss valves between the pump and tank may also be the reason; replace them with fully open gate valves to reduce friction loss.
  • B
    bethsmithAug 31, 2025
    How to fix little or no liquid delivered by Goulds J10?
    • A
      andersondavidSep 1, 2025
      If your Goulds Water Pump delivers little or no liquid, it could be due to several reasons. First, the pump might not be primed, the suction pipe submergence may be inadequate, or there could be an air leak in the suction pipe. Prime the pump and ensure the suction pipe is correctly submerged and free of leaks. Second, the discharge or suction may be plugged, or a valve may be closed; clear any blockages and ensure valves are open. Finally, the suction lift or suction losses may be excessive; reduce suction lift and minimize losses.

Summary

SAFETY INSTRUCTIONS

General Safety Warnings and Symbols

Explains DANGER, WARNING, CAUTION, NOTICE signals and general safety rules for pump operation.

Wiring Safety Notice

Important notice advising to read safety instructions before proceeding with any wiring.

SELECTING THE CORRECT JET PUMP SYSTEM

PREPARING FOR INSTALLATION

DEEP WELL TWIN PIPE SYSTEM

DEEP WELL PACKER SYSTEM

TECHNICAL DATA

Motor Voltage Change

Procedure for changing motor voltage from 115V to 230V and terminal board design.

TROUBLESHOOTING

Troubleshooting Symptoms and Causes

Lists common pump symptoms and their probable causes for diagnosis and repair.

GOULDS WATER TECHNOLOGY LIMITED WARRANTY

Warranty Terms and Exclusions

Details the warranty period, claims process, and exclusions for Goulds Water Technology pumps.

Goulds J10 Specifications

General IconGeneral
ModelJ10
CategoryWater Pump
Horsepower1 HP
TypeJet Pump
Voltage115/230 V
Phase1
MaterialCast Iron
Discharge Size1 inch
Impeller MaterialNoryl
Maximum Suction Lift25 feet
Suction Size1.25 inches

Related product manuals