    Jeffrey CarsonAug 9, 2025
    What to do if my Goulds J7 Water Pump delivers water but will not shut off?
    • J
      Jamie PetersAug 9, 2025
      If your Goulds Water Pump delivers water but doesn't shut off, it could be due to a plugged or incorrectly adjusted pressure switch. In this case, you should clean and adjust the pressure switch. Another potential cause is a defective suction check or foot valve, which would require replacement.
  • A
    Amy SmithAug 16, 2025
    Why is my Goulds Water Pump not running?
    • K
      Kaylee RichardsonAug 16, 2025
      If your Goulds Water Pump isn't running, there are several potential reasons. First, the motor thermal protector may have tripped; try resetting it. Second, check for an open circuit breaker or a blown fuse and replace them if necessary. Finally, the motor itself might be defective, requiring replacement.
  • S
    stacie03Aug 25, 2025
    What to do if my Goulds J7 cycles excessively?
    • M
      Mary DunlapAug 25, 2025
      If your Goulds Water Pump cycles excessively, it could be due to a water-logged pressure tank. Try draining and recharging the pressure tank. Another cause might be the pump being farther than 5 feet from the tank; move the pump closer. High friction loss valves between the pump and tank may also be the reason; replace them with fully open gate valves to reduce friction loss.
  • V
    Vanessa SavageSep 1, 2025
    How to fix little or no liquid delivered by Goulds J7 Water Pump?
    • T
      Travis TuckerSep 1, 2025
      If your Goulds Water Pump delivers little or no liquid, it could be due to several reasons. First, the pump might not be primed, the suction pipe submergence may be inadequate, or there could be an air leak in the suction pipe. Prime the pump and ensure the suction pipe is correctly submerged and free of leaks. Second, the discharge or suction may be plugged, or a valve may be closed; clear any blockages and ensure valves are open. Finally, the suction lift or suction losses may be excessive; reduce suction lift and minimize losses.

Summary

Selecting the Correct Jet Pump System

Shallow Well Jet Pumps

Built-in jet assemblies for maximum lift of 25', identified by one pipe to the well.

Installation Preparation

Deep Well Jet Pump Systems

Booster Systems Overview

Motor Power and Wiring

Technical Specifications

Shallow Well Suction Lift Checks

Pump Troubleshooting Guide

Motor Not Running

Probable causes and troubleshooting steps for when the pump motor does not start.

Low Liquid Delivery

Troubleshooting causes for low flow or no liquid delivery from the pump.

Pump Not Shutting Off

Causes and solutions for pumps that run continuously without shutting off.

Excessive Pump Cycling

Troubleshooting excessive pump cycling or short-cycling issues.