NP-210315_B441_IB_V1_01
Recyko Charger
B441
Quick Start Guide
Get started
Instruction
Download
Manual
1. Micro-USB charging port
2. LED indicator (Green)
3. Battery level check (For slot 1 & 4 only)
4. Terminal AA / AAA
5. Terminal AAA
6. Terminal AA
4
5
6
1
3
2
Question and Answer IconNeed help?

Do you have a question about the GP RECYKO B441 and is the answer not in the manual?

Overview

The GP Recyko B441 is a smart charger designed for NiMH rechargeable batteries, offering efficient and safe charging for both AA and AAA sizes. This quick start guide provides essential information for its operation, including connection, battery insertion, level checking, and charging procedures, along with important safety and maintenance guidelines.

Function Description:

The primary function of the GP Recyko B441 charger is to recharge NiMH AA and AAA batteries. It features four charging slots, with slots 1 and 4 also capable of performing a battery level check. The charger is designed for indoor use only and ensures optimal performance and safety when used with GP Recyko NiMH batteries. It supports charging in pairs, meaning batteries should be inserted into slots 1 and 2, or 3 and 4 for proper operation. The LED indicator provides visual feedback on the charging status and battery level, making it easy for users to monitor the process.

Important Technical Specifications:

  • Battery Compatibility: NiMH AA and AAA rechargeable batteries.
  • Number of Slots: 4 charging slots.
  • Input Power: Minimum 5V/1A via a Micro-USB charging port.
  • Charging Time (approximate, at 20°C ambient temperature):
    • AA (1300-2600 mAh): 2-8 hours (for 2 or 4 pcs)
    • AAA (650-950 mAh): 2.5-3.5 hours (for 2 or 4 pcs) Note: Charging time is subject to the power rating of the USB adaptor with 5V/1A DC output and varies depending on battery capacities.
  • Battery Storage Temperature: -20°C to +35°C.
  • Charging Operation Temperature: 0°C to +35°C.
  • LED Indicator Statuses:
    • Flashing: Low battery level (during check) or Charging (during operation).
    • Solid: Sufficient battery level (during check) or Full (after charging).
    • Rapid Flashing: Single-use or bad battery detected.
  • Battery Level Check Duration: 30 seconds (for slots 1 & 4 only).

Usage Features:

  1. Connect to Power: The charger is powered via a Micro-USB charging port (1). Connect it to a power source providing at least 5V/1A.
  2. Insert Batteries: Insert AA or AAA NiMH rechargeable batteries into the slots. For AA batteries, ensure the positive (+) terminal (4) aligns with the charger's positive terminal and the negative (-) terminal (6) aligns with the charger's negative terminal. For AAA batteries, the positive (+) terminal (4) aligns with the charger's positive terminal and the negative (-) terminal (5) aligns with the charger's negative terminal. It is crucial to insert batteries correctly, observing polarity.
  3. Battery Level Check: For slots 1 and 4, a battery level check (3) can be performed. The LED indicator (2) will show the battery status:
    • Flashing: Low battery level.
    • Solid: Sufficient battery level. The check lasts for approximately 30 seconds.
  4. Start Charging: The charger is designed to charge batteries in pairs. Insert batteries into slots 1 and 2, or 3 and 4.
    • Flashing LED: Indicates that batteries are currently charging.
    • Rapid Flashing LED: Signals that a single-use or bad battery has been detected, and charging will not proceed.
    • Solid LED: Indicates that the batteries are fully charged.
  5. Do's and Don'ts: The manual illustrates correct and incorrect ways to insert and charge batteries. Always charge in pairs (2 or 4 pieces) and ensure correct polarity. Do not mix battery types or charge single batteries in a 4-slot configuration. Do not insert batteries with incorrect polarity.

Maintenance Features:

  • Cleaning: The charger is maintenance-free but should be wiped clean regularly with a dry and soft cloth.
  • Avoid Abrasives and Solvents: Do not use abrasive materials or solvents for cleaning, as these can damage the device.
  • Disconnect Before Cleaning: Always unplug the charger from the power source before cleaning to prevent electrical hazards.
  • Storage: If the electrical device will not be used for a long time, remove the batteries. Store batteries within the recommended temperature range of -20°C to +35°C.
  • Safety Precautions:
    • Always use GP Recyko NiMH batteries for optimal performance and safety.
    • It is normal for batteries to become hot during charging; they will cool down to room temperature after being fully charged.
    • Do not charge other battery types, as this may lead to explosion, rupture, leakage, personal injury, or property damage.
    • The charger is for indoor use only. Do not expose it to rain, snow, or direct sunlight.
    • Do not use the charger in humid conditions or if the plug is damaged.
    • Do not use the charger if it has been dropped or damaged.
    • Do not open or disassemble the charger.
    • This appliance can be used by children aged 8 years and above, and persons with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, if they have been given supervision or instruction concerning safe use and understand the hazards involved.
    • Children should not play with the appliance. Cleaning and user maintenance should not be performed by children without supervision.
    • Dispose of electrical appliances in separate collection facilities, not as unsorted municipal waste, to prevent hazardous substances from leaking into groundwater and the food chain.