Batterycharger
Chargingoutputvoltage16.8Vrated;8-12Vunderload
Chargingoutputcurrent200-400mAunderload,1.4Amax
Charginginput100-240VAC;50/60Hz;1.5Amax.
Ratedpower23.52W
Operatingtemperature0°C…+40°C/+32°F...+105°F
Storagetemperature-20°C...+85°C/-4°Fto+185°F
WorkingconditionsIndooruseonly;notwaterproof(IP0)
NEMOGRABO®liftingcapacity
NOTICE:TheNemoGRABO®wastestedupto240kg(530lbs)atmaximumliftingforceunder
idealconditions.However,thisfigureisthebreakingpointunderoptimallabtestingconditionsand
mustneverbereachedinreal-worldapplications!
LocalregulationsrequiredifferentsafetymarginstobeusedandtheofficialtoolWorkingLoadLimit
(WLL)issetto120kg(265lbs)basedona2:1ratioonanon-poroussurface.TheWorkingLoadLimit
of120kg(265lbs)isone-halfofthetestedmaximumliftingforceunderidealconditions(240kg/530
lbs)andshouldbeadheredtowhenworkingincountrieswherethe2:1safetymarginapplies,
regardlessofthefactthatthechartbelowshowsamaximumliftingforceof170kg(375lbs).Inno
caseshouldtheNemoGRABO®beusedtoliftmorethan170kg(375lbs).Usethechartbelowto
estimatesafeliftingvalues:
WLL:120kg(265lbs)onnon-poroussurfaces
IMPORTANT:Theliftingforceishighlydependentontheliftedsurfaceandfactorssuchas
temperature,altitude(ambientpressure),andotherfactors.
AlwayscheckthepressuredisplayedontheNemoGRABO®PressuregaugeⒼ anddonotrely
solelyontheestimatedmaximumliftingforceschartwhenliftingdifferentmaterialssince
differentfactorsrelatedtoyourspecificapplicationmayreduceliftingcapabilitiesofthetool.
11
NEMO GRABO® | Operator’s manual