Performance Charts
20 308608L
Performance Charts
To find Pump Air Consumption (scfm or m
3
/min) at a specific fluid flow (gpm/lpm) and operating air pressure
(psi/bar):
1. Locate desired fluid flow along the bottom of the chart.
2. Follow vertical line up to the point of intersection with selected air consumption curve.
3. Align point on curve with vertical scale on left side of the chart to read air consumption.
Test Conditions: Pump tested with AW-32 oil at 75°F (24°C)
To find Fluid Outlet Pressure (psi/bar) at a specific fluid flow (gpm/lpm) and operating air pressure (psi/bar):
1. Locate desired fluid flow along the bottom of the chart.
2. Follow vertical line up to the point of intersection with selected fluid outlet pressure curve.
3. Align point on curve with vertical scale on left side of the chart to read fluid outlet pressure
Test Conditions: Pump tested with AW-32 oil at 75°F (24°C)