Causes of faults and how to repair
The following table helps repair and localise small faults:
Fault Possible cause Repair
The indicator lamp
does not illuminate
after switching on.
The plug is
not plugged in.
Plug in the plug.
Temperature monitoring
triggered.
Let the unit cool off.
Milk leaks from the
cap.
Filling level too high.
Reduce the lling
level.
The seal ring is missing
or soiled.
Clean the seal ring
and put it back in.
The cap is not correctly
set on.
Put the cap on in
such a manner that
it audibly latches.
IMPORTANT!
► If you cannot solve the problem with the above steps, please contact
our customer service department.