8. Fault messages and rectification
29 / 40
tered in the Service
menu are too high
Air compressor defec-
tive
Temperature sensor
defective
Temperature sensor is
missing
Temperature sensor is
not fully plugged into the
socket
Temperature sensor
defective
Replace sensor
Ensure secure connection between con-
troller and temperature sensor. Then
power off controller for 10 sec. and switch
it back on. Check whether a temp sensor
fault message is displayed.
Power failure
Plant switched off via
maintenance switch
No voltage on the switch
cabinet
FI fuse has blown
Wait for power to return
Switch plant on via maintenance switch
Check supply to the switch cabinet
Locate cause for triggering the RCCB and
correct it (possible cause: solenoid valve
defective).
Batteries in the module
are not yet fully charged
Modem has no mains
voltage
No SIM card inserted in
the modem
SIM card is not regis-
tered to the network
Wait 5 minutes until batteries are fully
charged
Connect modem to power
Insert SIM card in the modem
Wait until the card is registered. Other-
wise relocate antenna so that reception is
possible.