AUTOMATIC DIGITAL
BLOOD PRESSURE MONITOR
Model 1133
Instruction manual
Para instrucciones en Español, vease la pagina 25
1133-INS-LAB-RevD20

Questions and Answers

  • A
    Angelica RussellJul 28, 2025
    Why is my reading extremely low or high on the Graham Field LUMISCOPE 1133?
    • R
      Rodney LewisJul 28, 2025
      An extremely low or high reading on your Graham Field Blood Pressure Monitor can occur if the cuff is not at the same level as your heart, if the cuff is wrapped incorrectly, or if you are moving your arm, talking, or moving your hand during the measurement. Ensure correct posture, wrap the cuff correctly, relax, and keep quiet and silent during the measurement.
  • C
    Crystal MooreAug 4, 2025
    What to do if my Graham Field LUMISCOPE 1133 Blood Pressure Monitor pulse rate is too low or too high?
    • S
      Shannon MorrowAug 4, 2025
      If your pulse rate is too low or too high on the Graham Field Blood Pressure Monitor, it might be because you were talking or moving your arm or hand during the measurement, or if you took the measurement right after exercise. Keep quiet and silent during measurement. If you have just exercised, take the measurement again after resting for at least 5 minutes.
  • D
    Diane SullivanAug 9, 2025
    How to fix a Graham Field LUMISCOPE 1133 Blood Pressure Monitor that won't display after installing batteries?
    • J
      jallenAug 9, 2025
      If your Graham Field Blood Pressure Monitor doesn't display anything after installing batteries, the batteries may be depleted, the battery polarity may be incorrect, or the battery compartment contacts may be dirty. Replace all batteries with new ones, correct battery polarity, and clean the battery terminals with a dry cloth.
  • L
    Logan SpencerAug 16, 2025
    Why does my Graham Field LUMISCOPE 1133 automatically turn off?
    • D
      dustin54Aug 16, 2025
      The Graham Field Blood Pressure Monitor automatically turns off as a result of its automatic turn-off feature. This feature saves power consumption of the device and is not a fault.
  • N
    Nicole WardAug 22, 2025
    Why do the batteries deplete so quickly in my Graham Field Blood Pressure Monitor?
    • E
      Erin BenjaminAug 22, 2025
      If the batteries in your Graham Field Blood Pressure Monitor are depleting quickly, it may be due to faulty batteries. Use new alkaline batteries from known manufacturers.

Summary

General

Principle of Operation

Utilizes oscillometric technology and Fuzzy Algorithm to measure blood pressure and pulse rate by detecting arterial fluctuations via cuff pressure.

Usage Precautions

Includes warnings against outdoor use and requirements for specific temperature/humidity ranges for accurate readings.

Preparation for Measurement

Battery Installation

Details on opening the battery cover, installing four AA alkaline batteries with correct polarity, and closing the cover.

Setting the Date and Time

Carrying Out a Measurement

Memory Function

WHO Blood Pressure Classification Indication

Error and Low Battery Information

Maintenance, Storing, Repair and Recycling

Troubleshooting

Specifications

Manufacturers Declaration

Graham Field LUMISCOPE 1133 Specifications

General IconGeneral
CategoryBlood Pressure Monitor
BrandGraham Field
ModelLUMISCOPE 1133
Pressure Range0-300 mmHg
Gauge TypeAneroid
Cuff SizeAdult
Accuracy±3 mmHg
Inflation SystemManual
Deflation SystemManual
MaterialNylon Cuff