20
Error codes
Pr1 If error Pr1 is displayed, it means that the temperature sensor is defect.
Request service assistance.
In the meantime, the cabinet will aim to maintain the set temperature.
Pr2 If error Pr2 is displayed, there are problems with the evaporator sensor. The
sensor should be replaced as soon as possible. Request service assistance.
Defrosting
K/KG 210/410:
Defrosting is automatically performed 4 times every 24 hours, by circulating the air inside
the cabinet during compressor standstill periods. The defrost LED
lights to indicate
the defrosting cycle is running.
F/FG 210/410:
Defrosting is automatically performed 4 times every 24 hours, by a heating element
mounted at the evaporator.
Manual defrosting:
If the cabinet is operating under severe load (frequent door opening and frequent
replenishment), manual defrosting can become necessary.
Manual defrosting is performed as follows:
Push for 4 seconds, and defrosting is started. The defrost LED lights to indicate
the defrosting cycle is running.
Do not use sharp or pointed objects to accelerate the defrosting process.