shows
th
e ca
librate
value
,
like
[
1000.
00
]
,
then
put
the
corresponding
we
ight
on
the
pan softly. (This balance is intelligent calibration, it supports any integer point
calibration. If there is no corresponding value weight, it can be replaced by any
integer value weight within the range of no less than 1 / 10 of the maximum range.
The balance will automatically identify and calibrate the current value weight). Wait
for
approx
3s
until
the
displ
ay
shows
[
1000
.
00g
]
.
Please
remo
ve
the
weigh
t
and
it
will
be
bac
k
to
[
0.
00g
]
.
The
calibration
finished.
* Linearity Calibration Method
Sho
rt
press
“
TARE/CAL
”
key
to
make
the
balance
[
0.
00g
]
,
then
long
press
“
TARE/CAL
”
for
more
than
3s
to
until
the
displ
ay
shows
[
CAL
]
,
release the
“
TARE/CAL
”
key,
then
long
press
“
COU
”
key
until
it
shows
[
C
A
L
1
]
.
Pre
ss
“
UN
IT
”
o
r
“
COU
”
key
to
adjust
and select the linearity segments of the balance to be calibrated (for example, for a
balance
with
a
range
of
2kg,
when
[
C
A
L
4
]
is
selected,
it
means
that
it
is
divided
into four segments for calibration, with a difference of 500g in each segment, which
is
[
2000g
à
1500g
à
1000g
à
500g
]
in turn. Then press “
TARE/CAL
” key to enter
the linearity calibration, the balance will display an integer value. If the display
[
200
0.
00
]
flashes
,
put
2kg
standard
we
ight
softly
on
the
plate
,
wait
for
approx
3
seconds when the balance displays "2000.00g", remove the weight from the plate, it
will display another integer value, put the weight on the plate according to the
prompt value, and operate in turn until the balance automatically returns to zero
after removing the weight.
Convert Units
Balance as a measuring instrument, in order to meet the weighing requirements and
standards of various regions and industries, the balance has a multi-units for option.
The default unit is "g". Short press “UNIT” key to choose the different unit.
Zero
When the weight of the weighed object is not more than 2% of the total range, press
“
TARE/CAL
” key and the balance will return to zero. At this time, the
[
zero
]
indicator on the display will light up, and the balance can still be weighed in full
range.
Tare
When the weight of the weighed object is greater than 2% of the total range, press
“
TARE/CAL
”, and the balance will return to zero. At this time, the
[
tare
]
indicator on
the display will light up, and the balance can not be weighed in full range. You should
check the balance on the loading progress bar and weigh in the remaining range.