Test Report #: SHE-1402-11114-RF-#1
Prepared for Grandstream Networks, INC
Prepared by ECMG Electronic Technical Testing Corp (Shenzhen). Page 19 of 36
Transmitter e.i.r.p.(dBm), Limit = -10dBW
i.e. 20dBm/100mW
Remark:
EIRP=Read level + Antenna Gain + Cable Loss + 10log1/ (duty cycle)
1. The duty cycle of product is 100%, then 10log1/ (duty cycle) =0
2. Cable Loss offset 1dB in the spectrum.
3. Antenna gain=2.0dBi