Following adjustments are possible:
High Temp (HIT): set maximum temperature value for programming
fromlowtemperaturevalueupto+32°C(default:+32°C)
Low Temp (LOT): set minimum temperature value for programming
from+7°Cuptohightemperaturevalue(default:+15°C)
Frost protection (FRT): setantifreezeminimumtemperaturevaluefrom+3°Cto+7°C(default:5°C)
Regulation (REG): possibilitytoselectbetweenPIDor2pointsregulation(default:PID)
Differential (DIF): possibilitytomodifydifferentialvaluefrom0,1Kto0,9K(default:0,4K)
Keypad Lock (LOK): enable keypad to protect against non authorized interventions
To enable/disable the keypad lock press and hold MODE- and ESC-button for
more than 3 seconds.
Operating hours (OPT):thisfeatureshowstotaloperatingrunningtime(max.99.999hours)
Battery Level (BAT): battery charge level is shown on display