Promaster 100 Kohler 16 -18 HP
Normally open contacts. Large terminal contact resistance is 3 to 5 ohms.
Small terminal contact resistance is 0.1 to 0.3 ohms.
Normally open switches, manually activated.
Contact resistance is 0.1-0.3 ohms when correct.
Normally open switches, manually activated.
Contact resistance is 0.1-0.3 ohms when correct.
Time Delay Module Off Run Start
Brown 12.00 Vdc 12.00 Vdc
Yellow 12.00 Vdc 12.00 Vdc
Green 12.00 Vdc 12.00 Vdc
Solenoid Off Run Start
Brown (S1) 12.00 Vdc
Brown (S2) 12.00 Vdc 12.00 Vdc
Red (from battery) 12.00 Vdc 12.00 Vdc 12.00 Vdc
Red (to starter) 12.00 Vdc
PTO Interlock Switch Off Run Start
Brown 12.00 Vdc 12.00 Vdc
Brown/White 12.00 Vdc 12.00 Vdc
Seat Switch Off Run Start
Green/Green 12.00 Vdc 12.00 Vdc
Yellow/Yellow 12.00 Vdc 12.00 Vdc