13 - 72
Model 992010, 011 Kawasaki 18 HP, Briggs & Stratton
Normally open switches, manually activated.
Contact resistance is 0.1-0.3 ohms when correct.
Seat Switch Off Run Start
Yellow 12.00 Vdc 12.00 Vdc
Green Holding circuit for the time delay
Ignition Switch Off Run Start
Brown (S) 12.00 Vdc
Black (I) 12.00 Vdc 12.00 Vdc 12.00 Vdc
Purple (B) 12.00 Vdc 12.00 Vdc
Blue (R) 12.00 Vdc 12.00 Vdc
Green (A) 12.00 Vdc 12.00 Vdc
Time Delay Off Run Start
Orange 12.00 Vdc
Green 12.00 Vdc 12.00 Vdc
PTO Switch Off Run Start
Orange 12.00 Vdc 12.00 Vdc
Light Blue When selected to on position - 12. 00 Vdc
White (Clutch) Connected to ground