1.Specifications
Technical data pool heat pumps
Model
HPGI50
HPGI60
HPGI70
HPGI85
Code
74162
74163
74164
74165
* Performance at Air 28, Water 28, Humidity 80%
Heating capacity
kW
10-2.3
12-2.9
15-3.2
17-3.8
Power consumption
kW
1.55-0.14
1.77-0.18
2.26-0.2
2.67-0.23
C.O.P.
16-6.5
16-6.8
16-6.6
16-6.4
* Performance at Air 15, Water 26, Humidity 70%
Heating capacity
kW
7-1.9
8.5-2
10-2.2
12-3
Power consumption
kW
1.43-0.27
1.72-0.28
2.07-0.31
2.43-0.42
C.O.P.
7.1-4.9
7.2-4.9
7.2-4.8
7.2-4.9
* General data
Compressor type
Inverter Compressor
Voltage
V
220~240V / 50Hz /1PH
Rated current
A
6.9
7.9
10.0
11.8
Minimum fuse
A
10
12
15
18
Maximum pool
volume**
<55
<70
<80
< 95
Advised water flux
m
3
/h
2.8
3.7
4.0
4.6
Water pressure drop
Kpa
12
14
15
15
Heat exchanger
Twist-titanium tube in PVC
Water connection
mm
50
Ventilation type
Horizontal
Protection rating
IPX4
Max Pressure-suction
and discharge side
MPa
4.2
Noise level(10m)
dB(A)
22-34
23-35
23-37
24-37
Noise level(1m)
dB(A)
40-52
40-52
40-54
41-54
Refrigerant
R32
Refrigerant quantity
g
720
550
750
850
CO2 equivalent
Tonne
0.49
0.37
0.51
0.57
Net weight
kg
56
68
73
78
Gross weight
kg
68
73
78
83
Net dimension
mm
860*389*586.5
987*400.5*688
Packing dimension
mm
890*420*625
1015*435*713
* Above data is subject to update without prior notice.