Set the Temperature T
preset
Setting SLEEP function under HEAT mode, the preset temperature will automatically decrease by 1 after 1hour and
decrease by another 1 after 2 hours. Preset temperature will decrease by 2 in total within 2 hours. After that, the
unit will run at this preset temperature.
Set the Temperature T
preset
Setting SLEEP function under COOL or DEHUMIDIFY mode, the preset temperature will automatically rise by 1 after 1
hour and rise by another 1 after 2 hours. Preset temperature will rise by 2 in total within 2 hours. After that, the unit will ℃℃
run at this preset temperature.
If set sleep function under fan or auto mode, the
set temperature will remain unchanged.
6.2.3.8 Sleep Function
6.2.3.7 Indicator
There is a dual colour indicator on the running display section, after energized, if the unit is standby, the run indicator will
be red, and if the unit is running, the run indicator will be green. When defrosting, the heating indicator will blink.
6.2.3.5 Buzzer
When the controller is energized or receives remote control signal or the auto key be pressed, the buzzer will give out a beep.
6.2.3.6 Auto key
If one press of this key, the unit will run under AUTO mode and the indoor fan will run at AUTO SPEED.The swing motor
is started when the indoor fan is working. Press this key again to stop the unit.
STOP
Auto swing
6.2.3.4.2 Swing Left/Right
Once energized,the up and down swing motor will rotate the guide louver anticlockwise to position 0 to close the air outlet .If
swing between L and D position.There are 7 swing status for the guide louver : position L; A ; B; C; D; stop between L and D.
will be turned to L level position clockwise under other status. If swing function is set after the unit is started,the guide louver will
swing function is not set after the unit is started,the guide louver will be turned to D position clockwise
under heating status,and
when the unit is stop,the guide louver will be closed to 0 position. Only when the swing function is set and the indoor fan is
running, the the guide louver will swing.
T
B
preset
B
TB
preset
B+2
T
B
preset
B+1
1 hour
2 hours
Over 2 hours
TB
preset
B
TB
preset
B-1
T
B
preset
B-2
1 hour
2 hours Over 2 hours
Once energized,the left / right swing motor will drive the left / right guide louver to middle position.If swing left / right function is
left, hypo-left, middle, hypo-right, right, swing left and right and stop.(see below Fig.)
guide louver will stay at the set angle. When the L/R swing function is set, There are 7 swing status for the guide louver : position
not set after the unit is started,the guide louver will stay at middle position.If there is swing angle set by remote controller, the L/R
If set L/ R swing function when the unit start to run, the L/ R swing motor will drive the L/ R guide louver to swing left and
right. When cancel L/ R swing function , the guide louver will stay at current position. When the unit is switched off, the guide
louver will stay at original position. Only when the L/ R swing function is set and the indoor fan is running, the the guide louver
will swing.