Operating Procedures / Photos
Disassemble Capillary
Unsolder the soldering points of the capillary
subassembly and remove the capillary. Make
sure that do not let any welding dregs to block
Capillary
subassembly
(refer to Fig. 7-34)
(refer to Fig. 7-35)
(refer to Fig. 7-36)
Fig.7-36
Fig.7-35
Fig.7-34
the capillary.
Disassemble Valves
Unscrew the bolt fixing the valve,then
unsolder the soldering point between
the valve and the connect duct and
Valves
remove the valve.
bolt
Disassemble Compressor
Unsolder the two soldering points of the compressor,
Unscrew the three nuts at the foot of the compressor
and take out the compressor.
Foot Nut
soldering points