Operating Procedures / Photos
Disassemble axial-flow vane
Loosen tighten nut by spanner to take off nuts,
spring washer, flat washer, and take off axial-flow
vane forcibly.
(refer to Fig. 7-33)
(refer to Fig. 7-30)
(refer to Fig. 7-31)
tighten nut
axial-flow vane
Fig.7-31
Fig.7-32
Fig.7-33
Disassemble Motor and Motor Support
Unscrew the tapping screws fixing the motor,
and rem
ove the motor. Unscrew the two screws
fixing the motor support, and lift the motor support
to remove it.
Motor Support
tapping screws
Motor
Motor
wire
screws
(cooling only unit has not)
Screw off the holding nut of the 4-way valve coil
and remove the coil. Use wet cotton cloth to wrap
the 4-way valve, unsold the four soldering points
connecting the 4-way valve, and remove the
4-way valve. Be quick during the unsoldering
process, pay attention to keep the wrapping cloth
wet and do not allow the soldering flame to burn
the compressor lead-out cable.
4-way valve
nut
Disassemble 4-Way Valve