Butterfly Series
-
33
-
press auto button, runs at low speed. If T
set
-1 < T
in
< T
set
+1 , keep the previous running
state.
d. After auto mode running, if it detects 22 < T
in
< 26 , keep the previous running state.
Cooling & heating AUTO mode: in AUTO mode, when the machine is switched from heating
mode to the other modes, reversing valve becomes inactive in 90 seconds.
Cooling only AUTO mode: there is no heating function in this mode.
(3)protections
It is same as the one in cooling or heating mode.
E. other controls
1. SWING mode
a. When it is active, the louver returns to position O, close the air outlet.
b. When machine works, it turns to the max. Air output position D.
c. In swing state, the louver swings between position L and position D.
d. When the machine is switched off, it is back to position O.
e. When the machine is running and the swing is off, the louver stops at position E.
O
L
E
D
2. beeper
When PCB becomes active or receives the signal from the remote controller, the beeper will
beep.
3. indication lamps
it flashes when defrosting begin.
4. press the AUTO button a time, the machine runs in AUTO mode, indoor motor runs in low speed,
fresh air function is not active, press again the machine stops.
5. Automatic fan speed .
a. in cooling mode, if T
indoor
T
set
+ 5 high speed
T
indoor
T
set
+3 middle speed
T
indoor
T
set
+ 1 low speed
D
O
L
E