Owner's Manual
Air Conditioners
Models:
GMV-224WM/B-X
GMV-280WM/B-X
GMV-335WM/B-X
GMV-400WM/B-X
GMV-450WM/B-X
GMV-504WM/B-X
GMV-2460WM/B-X
Thank you for choosing Air Conditioners, please read this owner’s manual carefully before
operation and retain it for future reference.If you have lost the Owner’s Manual, please contact
the local agent or visit www.gree.com or sent email to global@gree.com.cn or electronic
version.
GREE reserves the right to interpret this manual which will be subject to any change due to
product improvement without further notice.
GREE Electric Appliances, Inc. of Zhuhai reserves the final right to interpret this manual.
D.C. Inverter
Multi VRF Modular

Other manuals for Gree GMV-504WM/B-X

Questions and Answers

  • R
    Rachel DunnAug 9, 2025
    Why is my Gree Air Conditioner not cooling or heating properly?
    • C
      Clayton CunninghamAug 9, 2025
      If your Gree Air Conditioner isn't cooling or heating correctly, several factors could be the cause: * Check for any obstructions blocking the air intake or outlet of either the indoor or outdoor unit and remove them. * Ensure that the temperature, fan speed, and wind direction are appropriately set using the wireless or wired controller. * Make sure doors and windows are closed, and draw curtains or louvers to block direct sunlight. * Reduce the number of heat sources in the room. * Clean the filter if it's blocked with dirt.
  • J
    Javier WestAug 19, 2025
    What to do if my Gree GMV-504WM/B-X doesn’t run?
    • J
      Jessica WoodAug 19, 2025
      If your Gree Air Conditioner isn't running, consider these potential causes: * **Power Supply:** Ensure the unit is properly connected to a power supply. * **Voltage:** Verify that the voltage is within the specified rating range. * **Fuse/Breaker:** Check for a broken fuse or tripped breaker and replace the fuse or reset the breaker. * **Remote Controller Battery:** Replace the batteries in the remote controller if they are weak. * **Remote Controller Range:** Make sure you are within the remote controller's operational range (8m).
  • D
    Destiny RobertsonAug 29, 2025
    What to do if my Gree Air Conditioner runs but stops immediately?
    • R
      Ricky DavisAug 29, 2025
      If your Gree Air Conditioner starts but then stops right away, it might be due to a blocked air intake or outlet on either the indoor or outdoor unit. Remove any obstructions to resolve this.

Summary

General Safety Precautions

Installation and Handling Safety

Follow instructions, use qualified personnel, ensure proper earthing, and check connections.

Operational Safety Precautions

Operational Safety Guidelines

Avoid inserting objects, ensure ventilation, do not operate with wet hands, and use caution during cleaning.

Preparation before Installation

Site Selection and Installation Guidelines

Provides critical instructions on selecting a suitable and safe location for unit installation.

Refrigerant Piping Specifications

Specifies the outer diameter and wall thickness requirements for refrigerant piping.

Connection Pipe

Overall Piping Connection Schematic

Illustrates the overall piping layout for connecting multiple outdoor and indoor units.

Pipe Length and Height Difference Limits

Defines limits for piping length and height differences between indoor and outdoor units.

R410 A Refrigerant Piping Specs

Details total length, farthest pipe length, and height difference limits for refrigerant piping.

Installation of the Connection Pipe

Connection Pipe Installation Precautions

Outlines principles for piping connection: short length, minimal bends, and proper radius.

Air Purging and Refrigerant Charge

Air Purging Process Steps

Describes the steps for performing air purging using a vacuum pump.

Refrigerant Charging for Piping

Guides on calculating and adding refrigerant for connecting pipes longer than 1m.

Total Refrigerant Charge Calculation

Explains how to calculate total refrigerant charge based on pipeline and module capacities.

Electric Wiring

Electrical Wiring Safety Precautions

Highlights safety and regulatory requirements for electrical wiring installation.

Power Cord Connection Procedure

Illustrates the correct method for connecting power cords to the units.

Circuit Breaker and Wire Size Specs

Provides tables for circuit breaker capacity and wire sizes based on unit models.

Power Cord Connection Safety Measures

Emphasizes safety precautions for connecting power cords, including grounding.

External Electrical Wiring Diagram

Single and Modular Unit Wiring Diagrams

Provides diagrams for external electrical wiring of single and modular VRF systems.

Check Items after Installation and Trial Run

Installation Completion Checklist

Lists crucial checks to perform after the unit installation is complete.

Trial Run Preparations and Notes

Details preparations and important notices before commencing the trial run.

Debugging Progress Stage Overview

Outlines the different stages of the debugging process with LED indicators.

Debugging: Startup Confirmation

Describes progress stage 12 for confirming the startup readiness.

Appendix: Normal Operational Parameter Judgment

Common Malfunction and Troubleshooting

General Malfunction Troubleshooting

Lists common phenomena, reasons, and measures for troubleshooting unit problems.

Unit Operation Malfunction Troubleshooting

Addresses issues like immediate stopping, mist from unit, and noise emission.

Error Indication

Interpreting Malfunction Codes

Explains how to interpret malfunction codes by combining symbols and numbers.

Indoor;Outdoor Unit Error Code Reference

Details specific error codes related to indoor and outdoor unit malfunctions.

Gree GMV-504WM/B-X Specifications

General IconGeneral
Heating Capacity16.0 kW
Power Supply380-415V/3Ph/50Hz
RefrigerantR410A
TypeVRF
Heating Capacity (BTU/h)54600 BTU/h