Owner's Manual
Original Instructions
Commercial Air Conditioners
GMV DC Inverter VRF
Models:
GMV-224WM/E-X
GMV-280WM/E1-X
GMV-280WM/E-X
……
GMV-2460WM/E-X

Table of Contents

Other manuals for Gree GMV-560WM/E-X

Questions and Answers

  • G
    Greg CamposJul 25, 2025
    What to do if my Gree GMV-560WM/E-X has communication failure between indoor and ODUs and IDU's communicator?
    • W
      wlewisJul 25, 2025
      If there is a communication failure between the indoor and outdoor units (ODUs) and the indoor unit's (IDU) communicator, check the network between the IDU and communicator. Also, if the communicator is disconnected, check the network between the IDUs and ODUs and between the IDU and communicator. Check if the cables connecting the control board of the ODU and the IDU and connecting the IDU and communicator are loose and reconnect them if needed. Alternatively, the communicator controller may be faulty, requiring replacement of the control board.
  • C
    Craig EllisJul 29, 2025
    What to do if my Gree GMV-560WM/E-X Air Conditioner has communication failure between main control board and inverter compressor drive?
    • A
      Alan AustinJul 29, 2025
      If there is a communication failure between the main control board and the inverter compressor drive, check if the cable connecting the control board and the compressor's drive board is loose and reconnect it if necessary. Also, check if the cable connecting the control board and compressor's drive board is broken and replace it if needed. Check the contact of the communication cable connecting the control board and compressor's drive board. If the communicator is faulty, replace the control board.
  • F
    fmcguireAug 2, 2025
    Why does my Gree GMV-560WM/E-X Air Conditioner show power phase sequence protection?
    • K
      Katherine ScottAug 2, 2025
      Power phase sequence protection can occur if the three-phase power cable is not connected correctly. Check the connection of the power cable. Alternatively, the control board may need to be replaced.
  • C
    Chloe VargasAug 7, 2025
    What to do if my Gree GMV-560WM/E-X has faults in the constant frequency compressor's current sensor?
    • A
      Amy OrtizAug 7, 2025
      If there are faults in the constant frequency compressor's current sensor and the compressor is not starting, check if the AC contact is closed. If not, replace the AC contact. If the connection is loose, reconnect it. Also, consider replacing the current detection board or the main board.
  • Z
    zleeAug 12, 2025
    How to fix wrong outdoor capacity code setting on my Gree GMV-560WM/E-X Air Conditioner?
    • V
      Veronica JonesAug 12, 2025
      If the outdoor capacity code setting is wrong because the capacity code is incorrect, modify the capacity code setting. Alternatively, the main board may need to be replaced.
  • A
    Andrew FordAug 15, 2025
    What to do if my Gree Air Conditioner has faults in the ODU's main board?
    • S
      Sydney DaughertyAug 16, 2025
      If there are faults in the ODU's main board, such as memory and address chip exceptions, replace the small CPU board. You may also need to replace the control board.
  • M
    Megan BensonAug 20, 2025
    How to fix wrong emergency operation dial code on Gree GMV-560WM/E-X?
    • B
      brittanysantiagoAug 20, 2025
      If the emergency operation dial code is wrong because the dial setting is incorrect, modify the dial setting. Alternatively, the main board may need to be replaced.

Summary

Safety Notices and Precautions

Gree VRF Product Introduction

Names of Main Parts

Identifies the main components of the outdoor unit.

Combinations of Outdoor Units

Details various outdoor unit model combinations.

Combinations of Indoor and Outdoor Units

Specifies compatible indoor and outdoor unit pairings.

Range of Production Working Temperature

Defines the operational temperature limits for the VRF system.

Installation Preparation and Requirements

Standard Parts Included

Lists standard parts provided with the outdoor unit.

Installation Site Selection

Guidelines for choosing a suitable installation location.

Piping Work Requirements

Specifications for refrigerant piping installation.

Comprehensive Installation Guide

Outdoor Unit Physical Dimensions and Mounting

Provides dimensions and mounting hole details for outdoor units.

Connection Pipe Details

Details on refrigerant pipe diagrams, lengths, and installation procedures.

Air Purging and Refrigerant Charge

Procedures for air purging and adding refrigerant.

Electric Wiring Guide

Instructions for electrical wiring and power cord connection.

System Communication Setup

Guidance on setting up system communication.

External Electrical Wiring Diagrams

Diagrams illustrating external electrical connections.

Post-Installation Checks and Trial Run

Installation Check Items

Checklist for verifying installation correctness.

Trial Run Procedure

Steps and notices for conducting the trial run.

Appendix: Operational Parameter References

Reference values for normal operational parameters.

Troubleshooting Common Malfunctions

Error Indication and Codes

Indoor Unit Error Codes

List and explanation of error codes for indoor units.

Outdoor Unit Error Codes

List and explanation of error codes for outdoor units.

Maintenance and Care Procedures

Outdoor Heat Exchanger Cleaning

Instructions for cleaning the outdoor heat exchanger.

Drain Pipe Inspection

Procedure for checking the drain pipe for blockages.

Seasonal Use Preparation

Checks before seasonal use of the unit.

Post-Seasonal Use Maintenance

Maintenance tasks after the unit has been out of season.

Parts Replacement Guidelines

Guidance on purchasing and replacing parts.

After-Sales Service and Warranty Information

Gree GMV-560WM/E-X Specifications

General IconGeneral
BrandGree
ModelGMV-560WM/E-X
CategoryAir Conditioner
LanguageEnglish