EasyManua.ls Logo

Gree GMV-335WL/C-X - User Manual

Gree GMV-335WL/C-X
101 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Owner's Manual
Original Instructions
Commercial Air Conditioners
DC Inverter Multi VRF System
Models:
GMV-H224WL/A-X
GMV-H280WL/A-X
GMV-H335WL/A-X
GMV-224WL/C-X
GMV-280WL/C-X
GMV-335WL/C-X
Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.

Table of Contents

Other manuals for Gree GMV-335WL/C-X

Questions and Answers:

Gree GMV-335WL/C-X Specifications

General IconGeneral
Cooling Capacity33.5 kW
Heating Capacity37.5 kW
Power Supply380-415V/3Ph/50Hz
RefrigerantR410A
Operating Temperature (Cooling)-5°C to 48°C
TypeVRF
Operating Temperature (Heating)-20°C to 24°C

Summary

Preface

Correct Disposal of this product

Environmental guidelines for product disposal according to EU regulations.

Safety Precautions

Product Introduction

Names of Main Parts

Identifies key components of the outdoor unit.

Preparation before Installation

Combinations of Indoor and Outdoor Units

Details how many indoor units can connect to an outdoor unit.

Operating Range

Specifies operational temperature limits for cooling and heating.

Standard Parts

Lists essential parts supplied with the outdoor unit for installation.

Installation Site

Piping Work Requirements

Installation Instruction

Dimension of Outdoor Unit and Mounting Hole

Provides outline and installation dimensions for various outdoor unit models.

Connection Pipe

Details the requirements for connecting refrigerant pipes.

Schematic Diagram of Piping Connection

Illustrates the general piping connection layout from ODU to IDUs.

Allowable Length and Height Difference of Connection Pipe

Details the permitted lengths and height differences for connection pipes.

Dimension of Pipe (Main Pipe) from ODU to the 1 st Indoor Branch

Specifies pipe dimensions for the main line from ODU to the first branch.

Selection of Indoor Branches

Guides selection of indoor branches based on total downstream capacity.

Dimension of Pipe between Indoor Branches

Details pipe sizing for connections between indoor branches.

Dimension of Pipe between Indoor Branch and IDU

Specifies pipe dimensions for connections between indoor branches and individual IDUs.

Installation of Connection Pipe

Precautions for the Installation of Connection Pipe

Lists key principles and precautions for connecting pipes.

Flaring Process

Details the steps and precautions for flaring connection pipes.

Pipe Bending

Indoor Pipe Connection

Outdoor Pipe Connection

Installation of Y-type Branch

Thermal Insulation for Pipeline

Support and Protection of Pipeline

Vacuum Pumping, Refrigerant Adding

Vacuum Pumping

Details the process of vacuum pumping for the system.

Refrigerant Adding

Explains how to calculate and add refrigerant to the system.

Electric Wiring

Notices for Wiring

Provides important notices and precautions regarding electrical wiring.

Wiring Diagram

Shows diagrams for power and communication wire connections.

Engineering wiring of power supply and communication cable

Guides the technical wiring of power supply and communication cables.

Check Items after Installation and Test Operation

Check Items after Installation

Lists crucial checks to perform after the installation is complete.

Test operation and debugging

Prepare the test operation and debugging

Lists preparatory steps before conducting test operation and debugging.

Test Operation and Debugging

Describes test procedures and ODU main board displays during debugging.

Common Malfunctions and Troubleshooting

Error Indication

Function Setting of Outdoor Unit

ODU Quiet Function

Allows setting quiet modes for noise-sensitive projects.

Cool & Heat Function

Sets operation modes and prevents conflicts between indoor units.

Forced Defrosting

Enables manual initiation of the defrosting cycle for the outdoor unit.

Restore Factory Defaults

Explains how to reset unit settings to factory defaults.

Static Pressure Function

Allows adjustment of static pressure for heat exchange in specific installation areas.

Maintenance and Care

Outdoor Heat Exchanger

Instructions for cleaning the outdoor heat exchanger.

Drain Pipe

Guidance on checking and ensuring the drain pipe is clear.

Notice before Seasonal Use

Pre-season checks for indoor and outdoor units.

Maintenance after Seasonal Use

Procedures for maintenance after the unit has been used seasonally.

Parts Replacement

Information on how to obtain replacement parts.

After-sales Service

Related product manuals